1-1 BASIC_GET / MULTILEVEL_SWITCH_GET 

Upon receipt of the following commands from a Z-Wave Controller, the Switch will 

report its dimmer state to the node inquired. 

Basic Get Command: 

[Command Class Basic, Basic Get]

 

Basic Report Command: 
Report OFF: 

[Command Class Basic, Basic Report, Value = 0]

 

Report ON:

[Command Class Basic, Basic Report, Value = 1~99]

 

 

Multilevel Switch Get Command:

[Command Class Multilevel Switch, Multilevel 

Switch Get]

 

Multilevel Switch Report Command: 
Report OFF:

[Command Class Multilevel Switch, Multilevel Switch Report, 

Value=0]

 

Report ON:

[Command Class Multilevel Switch, Multilevel Switch Report, Value 

=1~99]

 

1-2 BASIC_SET / MULTILEVEL_SWITCH _SET 

Upon receipt of the following commands from a Z-Wave Controller, the load 

attached to the dimmer will turn on or off. 

[Command Class Basic, Basic Set, Value = 0] : 

the load attached to the 

dimmer turns off.

 

[Command Class Basic, Basic Set, Value = 1~99] : 

the attached load dim on as 

the level.

 

 

[Command Class Multilevel Switch, Multilevel Switch Set, Value=0, Duration = 
0~255] : 

the load attached to the dimmer turns off.

 

[Command Class Multilevel Switch, Multilevel Switch Set, Value =1~99, 
Duration = 0~255] : 

the attached load dim on as the level.

 

1. 

Z-

Wave’s Groups 

 

The Switch can be set to send reports to associated Z-Wave devices. It supports 

one association group with five nodes support for grouping 1. For group 1, the dimmer 

will report MULTILEVEL_SWITCH_REPORT, ALARM_REPORT and 

DEVICE_RESET_LOCALLY_NOTIFICATION. 

2-1 Grouping 1 Lifeline(Maximum 5 nodes) 

2-1-1 Device reset locally notification : 

When PAD07 is reset manually, it will send a DEVICE_RESET_LOCALLY_ 

NOTIFICATION to the nodes of group 1. 

2-1-2 On/Off Event Report 

Wh

en “on” or “off ” state has been changed, it will send Multilevel Switch Report to the 

nodes of Grouping 1. 

Multilevel

 Switch Report

 

ON:

[Command Class Multilevel Switch, Multilevel Switch Report, Value 

=1~99]

 

OFF:

[Command Class Multilevel Switch, Multilevel Switch Report, Value 

=0(0x00)]

 

2-1-3 Overload alarm report 

When PAD07 detects the Overload, it will send Alarm Report to Group 1 nodes. After 

detecting overload state and sending this alarm report, PAD07 will turn off the dimmer 

automatically and lockout the On/Off button and S1/S2. The only thing to do is unplug 

PAD07 and reduce the load. Then re-power on PAD07 and it will work again.

 

The content of Alarm Report

 

Alarm report command: 

[Command_Class_Alarm, Alarm_Report, Alarm Type = 

0x08, Alarm Level = 0xFF]

 

2-2 Grouping 2 Control_Key1 : (Maximum 5 nodes) 

When the On/Off status changes or the dim level is achieved manually, it will send 

BASIC_SET command to group 2 nodes to make them unanimous.

 

Dimmer Off : [Command Class Basic, Basic Set, Value = 0] 

 

Dimmer On : [Command Class Basic, Basic Set, Value = 1~99] 

 

 

3.

 Z-

Wave’s Configuration

 

Configuration 

Parameter

 

Function

 

Size 

(Byte)

 

Value

 

Unit

 

Default

 

Description

 

1

 

Dimmer Level 
Report mode

 

1

 

0-1

 

 

1

 

0 : Disable 

1 : Enable

 

2

 

LED indication 
mode

 

1

 

1-3

 

 

1

 

1: Show dimmer state 

2 : Show night mode 

Содержание PAD07

Страница 1: ...with a Secured enabled controller to fully utilize the device Its functionality and supported command classes is identical when included as a secure and non secure device Adding to Z WaveTM Network In the front casing there is an on off button also an include button with LED indicator below which is used to dim on and off or carries out inclusion exclusion reset or association When first power app...

Страница 2: ...ause the PAD07 to send its NIF 2 There are two groups for the dimmer Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller LED Indication To distinguish what mode the switch is in view from the LED for identification State Type LE...

Страница 3: ...will report MULTILEVEL_SWITCH_REPORT ALARM_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION 2 1 Grouping 1 Lifeline Maximum 5 nodes 2 1 1 Device reset locally notification When PAD07 is reset manually it will send a DEVICE_RESET_LOCALLY_ NOTIFICATION to the nodes of group 1 2 1 2 On Off Event Report When on or off state has been changed it will send Multilevel Switch Report to the nodes of Grouping 1 ...

Страница 4: ...m down to Off 3 4 restore dimmer state Whenever the AC power return from lost PAD07 will restore the switch state which could be Dimmer off Last dimmer state Dimmer on The default setting is Last dimmer state 4 Firmware update over the air OTA PAD07 is based on 500 series SoC and supports Firmware Update Command Class it can receives the updated firmware image sent by controller via the Z wave RF ...

Страница 5: ...Minimum 40 m in door 100m outdoor line of sight Modulation Type FSK Frequency Shift Keying Specifications are subject to change and improvement without notice FCC ID RHHPAD07 Warning Do not use Non Dimmable LED lamps DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulations Any works introducing changes into th...

Страница 6: ...nterference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television rec...

Отзывы: