5
The dimmer LED
illuminating, but cannot
control the ON/OFF
state of the load
attached
Check if the load
connected to the dimmer
has its own ON/OFF
switch
Set the ON/OFF switch of the load attached
to ON
The dimmer LED
illuminating, but the
Detector cannot control
the Switch
1. Not carry out association
2. Same frequency
interference
1. Carry out association
2. Wait for a while to re-try
Specification
Input Rating:(Operating Voltage)
100-240Vac / 50Hz-60Hz
Input Rating:(Operating Current)
0.01~1A ; (Maximum: 1A)
Output Rating: Maximum Load (Current)
Maximum: 0.9A (100-240Vac)
Output Rating: Maximum Load
(watts)(230V)
200W (13W x 15 pieces) (Dimmable LED bulbs)
(230Vac)
Output Rating: Maximum Load
(watts)(120V)
100W (13W x 15 pieces) (Dimmable LED bulbs)
(120Vac)
Output Rating: Maximum Dimmable LED
bulbs
Maximum: 15 pieces (Dimmable LED bulbs)
Operating Temperature
0°C ~ 40°C
Frequency Range
868.40MHz & 869.85MHz/ EU (PAD07-EU);
908.4MHz & 916.0MHz/ USA (PAD07-US);
RF Maximum Power
+5dBm
Transmission Range
Minimum 40 m in door 100m outdoor line of sight
Modulation Type
FSK (Frequency-Shift Keying)
** Specifications are subject to change and improvement without notice.
FCC ID : RHHPAD07
Warning: Do not use Non-Dimmable LED lamps.
DANGER
Danger of electrocution!
All works on the device may be performed only by a qualified and licensed electrician.
Observe national regulations.
Any works introducing changes into the configuration must be always performed with
disconnected voltage.
Choosing a Suitable Location
1. Do not locate the Module facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Module is 0°C~40°C.
3. Do not locate the Module where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of Module will become a little bit hot of which
phenomenon is normal.
Warning:
1.Plug out to disconnect from power supply; Do not plug in line.
2. Do not exceed the max rating.
3. Do not use Non-Dimmable LED lamps.
IMPORTANT
Installation must be performed by skilled technicians who are informed about the
standards and
technical requirements of the appliance and its proper installation.