EN - 7
06/2012
Copyright © 2012, Fast ČR, a. s.
Location
The location for the placement of the appliance must meet the requirements in the paragraph "Operating
conditions" and must have a stable fl oor with a load bearing capacity corresponding to the weight of the appliance.
This appliance is designed to be built-in.
Furthermore you must maintain distances and dimensions of the appliance, so that correct operation
is ensured:
1. Top part at least 20 cm;
2. Rear part at least 10 cm;
3. The wall on the side where the door opens at least 30 cm.
Ventilation requirements
The area behind the appliance must provide for suffi
cient air circulation.
Level the appliance using the adjustable feet, ensure there is a gap between the bottom edge of the appliance
and the ground, so that there is suffi
cient circulation of the cooling air, by which you will ensure the optimal
performance of the cooling circuit.
Check whether any cooling circulation pipes have been damaged during the installation.
Use the appliance only for the purposes for which it has been designed.
The appliance must be located on a rigid and even surface.
In this way you will ensure free circulation of the coolant and eff ective operation of your appliance.
If possible, place the appliance into a cool, well ventilated and dry room.
Do not locate the appliance in direct sunlight, or in a room with a high temperature, in the vicinity of any
sources of direct heat, such as heating, an oven, a stove, etc. – this would mean that the compressor would
need to work a lot harder resulting a substantially higher power consumption level.
If it is not possible to prevent the installation in the vicinity of a heat source, we recommend the insertion of an
appropriate insulating board (do not use asbestos) between the appliance and the heat source; or at least to
maintain the following minimum distances:
From a gas or electric stove 3 cm;
From a heater or oven, etc. 30 cm;
From another cooling appliance 2 cm.
Do not place any appliances on the appliance, which release heat on to the appliance, such as microwave
ovens, toasters, etc.
Содержание PTF 8211 BU
Страница 1: ...UPRIGHT FREEZER USER S MANUAL PTF 8211 BU...
Страница 20: ......
Страница 21: ...UPL KOV MRAZ K N VOD K OBSLUZE PTF 8211 BU...
Страница 27: ...CZ 5 06 2012 Copyright 2012 Fast R a s ST 2 POPIS P STROJE 1 2 1 Z suvky mraz ku 2 Ovlada termostatu...
Страница 40: ......
Страница 41: ...Z SUVKOV MRAZNI KA N VOD NA OBSLUHU PTF 8211 BU...
Страница 47: ...SK 5 06 2012 Copyright 2012 Fast R a s AS 2 POPIS PR STROJA 1 2 1 Z suvky mrazni ky 2 Ovl danie termostatu...