EN - 13
10/2016
Copyright © 2016, Fast ČR, a. s.
Troubleshooting
CAUTION!
Before troubleshooting, disconnect the power supply. Only a qualifi ed electrician of competent
person must do the troubleshooting that is not in this manual.
IMPORTANT!
There are some sounds during normal use (compressor, refrigerant circulation).
Problem
Possible cause
Solution
Appliance dose
not work
Mains plug is not plugged in or is loose
Insert mains plug.
Fuse has blown or is defective
Check fuse, replace if necessary.
Socket is defective
Mains malfunctions are to be corrected
by an electrician.
Appliance freezes
too much
Temperature is set too cold or the
appliance runs at MAX setting.
Turn the temperature regulator to
a warmer setting temporarily.
The food is not
frozen enough.
Temperature is not properly adjusted.
Please look in the initial Temperature
Setting section.
Door was open for an extended period.
Open the door only as long as necessary.
A large quantity of warm food was
placed in the appliance within the last
24 hours.
Turn the temperature regulation to
a colder setting temporarily.
The appliance is near a heat source.
Please look in the installation location
section.
Heavy build-up of
frost on the door
seal.
Door seal is not air-tight.
Carefully warm the leaking sections of
the door seal with a hair dryer (on a cool
setting). At the same time shape the
warmed door seal by hand such that it
sits correctly.
Unusual noises
The appliance is touching the wall or
other objects.
Move the appliance slightly.
A component, e.g. a pipe, on the rear of
the appliance is touching another part of
the appliance or the wall.
If necessary, carefully bend the
component out of the way.
If the malfunction shows again, contact the Service Center.