QP-10-IM21UL/Rev 12

 

Diffused horizontal irradiance 

 

Installation height of bifacial module 

is  recommended  to  be  higher  than  1 

meter  in  order  to  harvest  maximum 

available  reflected  and  diffused 

radiation and to reduce shading on the 

backside. 

 

Structure,  cables  and  any  other 

component  of  installation  should  not 

cause shading on the backside of the 

modules. 

 

TILT

 

ANGLE: 

The  tilt  angle  of  the  PV  module  is  the  measured  between  the PV  module  and  a 

horizontal  ground  surface.  The  PV  module  generates  the  maximum  output  power 

when it faces the sun directly. 5 degrees or more is recommended for the tilt angle of 

the PV module for the maintenance. 

For the stand alone systems with a battery where the PV modules are attached to a 

permanent  structure,  the  tilt  angle  of  the  PV  modules  should  be  determined  to 

optimize the performance when the sunlight is the scarcest, In general, if the electric 

power  generation  is  adequate  when  the  sunlight  is  the  scarcest,  then  the  angle 

chosen  should  be  adequate  during  the  rest  of  the  year.  For  Grid-connected 

installations  where  the  PV  modules  are  attached  to  a  permanent structure,  it  is 

recommended  to  tilt  the  PV  module  at  the  angle  equal  to  the  latitude  of  the 

installation site  so that the power generation from the PV module  will  be  optimum 

throughout the  year. 

Artificially concentrated sunlight shall not be directed to the panel, or module. 
 

 

Содержание PS-M60 Series

Страница 1: ...Installation...

Страница 2: ...ect PV Modules cables from direct sunlight 6 Do not strain junction box conductors 7 Do not touch any surface ofmodule 8 Do not place drop objects onto the PVmodule 9 Do not disassemble or attempt to...

Страница 3: ...reserves the right to make changes to the product specifications or installation manual without prior notice GENERAL INFORMATION The installation of PV modules requires a great degree of skill and sho...

Страница 4: ...s most likely to be damaged In the case of a brush type motor the coil is most likely to be damaged GERNERAL SAFETY Consult local codes and other applicable laws concerning required permits on regulat...

Страница 5: ...a risk of frost damage when the frame is filled with water accumulation When sliding snow load has to be considered an appropriate measure has to be taken so that PV module frames on lower edge of PV...

Страница 6: ...t stand or step on the PV module The glass surface of PV is slippery and that would cause microcracks in cells which affect the power generation Do not hit or put excessive load on the glass or in the...

Страница 7: ...get hot There is a risk of burn or you may collapse because of electric shock Do not work under rain snow or windy conditions Use insulated tools Do not use wet tools Donotdroptoolsorhard objects onP...

Страница 8: ...be exposed to direct sunlight after installation to prevent degradation of cables SITE SELECTION In most applications the PV modules should be installed in a location where there is no shading throug...

Страница 9: ...he tilt angle of the PV module for the maintenance For the stand alone systems with a battery where the PV modules are attached to a permanent structure the tilt angle of the PV modules should be dete...

Страница 10: ...Insulation for DC cables according to IEC712 7 60364 The frame grounding must consider the local requirements and regulations at the site of installation When grounding is required please refer to the...

Страница 11: ...or electrical conductivity Such devices where supplied with the module and evaluated through the requirements in UL 61730 may be used for grounding connectionsin accordance with the instructions provi...

Страница 12: ...modules clamps should not contact module s glass or deform module s frame 2 Make sure to avoid shadowing from using clamps 3 Make sure to avoid modifying module s frame 4 Use 4 clamps on the long sid...

Страница 13: ...el of load Condition applies to most of the environmental conditions Use four mounting holes applies to harsher environmental conditions such as storm heavy snow etc use eight mounting holes Clamping...

Страница 14: ...max are within 5 under STC conditions Irradiance of 1000W m2 Am 1 5 spectrum and ambient Temperature of 25C The operating Temperature range 40 C to 85 C under IEC standards 40 C to 90 C under UL 6173...

Страница 15: ...contact access is anticipated modules qualified for safety through EN IEC 61730 1 and IEC 61730 2 within this application class are considered to meet the requirements for safety class II Fuses The m...

Страница 16: ...mate conditions PS modules are designed and tested to withstand harsh conditions for more than 25 years In addition to the required IEC certification to meet European standards PS products have also b...

Страница 17: ...ge at NMOT in Watt 274 281 225 230 244 252 196 204 274 280 225 230 Open Circuit Voltage Voc at NMOT v 45 6 46 68 37 37 38 8 44 5 44 35 36 4 37 43 45 95 47 43 38 96 39 20 Short Circuit Current Isc at N...

Отзывы: