QP-10-IM21UL/Rev 12

 

 

Do not work alone and work as a team. 

 

Wear a safety belt if working far above the ground. 

 

Do not wear metallic jewelry which can cause electric shock during installation. 

 

Do not damage the back sheet of PV modules when fastening the PV modules to a 

support by bolts. 

 

Do not damage the surrounding PV modules or mounting structure when replacing 

a PV module. 

 

Bind cables by the installation locks. Drooping down of cables from the terminal box 

could possibly cause various problems such as animal biting, electricity leakage in 

puddle. 

 

Take  proper  measures  for  preventing  the  laminate  (consisted  of  resin,  cells,  and 

glass, back sheet …etc.) from dropping out of the frame in case the glass is   broken.

 

 

Cables  shall  be  located  so  that  they  will  not  be  exposed  to  direct  sunlight  after 

installation to prevent degradation of cables. 

SITE SELECTION: 

In most applications, the PV modules should be installed in a location where there is 

no  shading  throughout  the  year.  The  PV  panels  face  south  In  the  Northern 

Hemisphere. 

Please make sure that there are  no obstructions in the surroundings  of  the  site of 

installation. Take proper steps in order to maintain reliability and safety, in case the 

PV  modules  are  used  in  areas  such  as:  Heavy  snow  areas/Extremely  cold 

areas/strong wind areas/installation over, or near, water/Areas where installations 

are prone to saltwater damage/small islands or desert areas. 

Lightning  protection  is  recommended  for  PV  systems  that  are  to  be  installed  in 

locations with high probability of lightning strikes. 

For Bifacial Modules: 

 

The energy output of bifacial module can be affected by albedo of the ground 

that  module  installed  on,  height  of  module,  Ground  coverage  Ratio  (GCR),  and 

Содержание PS-M60 Series

Страница 1: ...Installation...

Страница 2: ...ect PV Modules cables from direct sunlight 6 Do not strain junction box conductors 7 Do not touch any surface ofmodule 8 Do not place drop objects onto the PVmodule 9 Do not disassemble or attempt to...

Страница 3: ...reserves the right to make changes to the product specifications or installation manual without prior notice GENERAL INFORMATION The installation of PV modules requires a great degree of skill and sho...

Страница 4: ...s most likely to be damaged In the case of a brush type motor the coil is most likely to be damaged GERNERAL SAFETY Consult local codes and other applicable laws concerning required permits on regulat...

Страница 5: ...a risk of frost damage when the frame is filled with water accumulation When sliding snow load has to be considered an appropriate measure has to be taken so that PV module frames on lower edge of PV...

Страница 6: ...t stand or step on the PV module The glass surface of PV is slippery and that would cause microcracks in cells which affect the power generation Do not hit or put excessive load on the glass or in the...

Страница 7: ...get hot There is a risk of burn or you may collapse because of electric shock Do not work under rain snow or windy conditions Use insulated tools Do not use wet tools Donotdroptoolsorhard objects onP...

Страница 8: ...be exposed to direct sunlight after installation to prevent degradation of cables SITE SELECTION In most applications the PV modules should be installed in a location where there is no shading throug...

Страница 9: ...he tilt angle of the PV module for the maintenance For the stand alone systems with a battery where the PV modules are attached to a permanent structure the tilt angle of the PV modules should be dete...

Страница 10: ...Insulation for DC cables according to IEC712 7 60364 The frame grounding must consider the local requirements and regulations at the site of installation When grounding is required please refer to the...

Страница 11: ...or electrical conductivity Such devices where supplied with the module and evaluated through the requirements in UL 61730 may be used for grounding connectionsin accordance with the instructions provi...

Страница 12: ...modules clamps should not contact module s glass or deform module s frame 2 Make sure to avoid shadowing from using clamps 3 Make sure to avoid modifying module s frame 4 Use 4 clamps on the long sid...

Страница 13: ...el of load Condition applies to most of the environmental conditions Use four mounting holes applies to harsher environmental conditions such as storm heavy snow etc use eight mounting holes Clamping...

Страница 14: ...max are within 5 under STC conditions Irradiance of 1000W m2 Am 1 5 spectrum and ambient Temperature of 25C The operating Temperature range 40 C to 85 C under IEC standards 40 C to 90 C under UL 6173...

Страница 15: ...contact access is anticipated modules qualified for safety through EN IEC 61730 1 and IEC 61730 2 within this application class are considered to meet the requirements for safety class II Fuses The m...

Страница 16: ...mate conditions PS modules are designed and tested to withstand harsh conditions for more than 25 years In addition to the required IEC certification to meet European standards PS products have also b...

Страница 17: ...ge at NMOT in Watt 274 281 225 230 244 252 196 204 274 280 225 230 Open Circuit Voltage Voc at NMOT v 45 6 46 68 37 37 38 8 44 5 44 35 36 4 37 43 45 95 47 43 38 96 39 20 Short Circuit Current Isc at N...

Отзывы: