4.4
GUI Parametric Information:
This section allows users to review, but not edit, Parametric Information for each port.
Figure 24: Parametric Information
The Port Parametric Information panel has the following set of parameters that are displayed:
• Discovery R (ohms) – This value represents the discovered resistance (R) of the port in ohms.
• Current (mA) – This value represents the current (I) of the port in milliamperes
• Voltage (V) – This value represents the voltage (V) of the port.
• Power (mW) – This value represents the power of the port in milliwatts.
• Class Current (mA) – This value represents the class current of the port in milliamperes.
• Determined Class – This value represents the class of the discovered device.
Note:
If the ports are less than 24-ports for the system those ports greater than the total system port
count will read all zeros “0”. In the figure above, Port 1 is connected to a compliant load while
Ports 2-24 are ready to be connected.