• This AC charger supports different power grid connections and
grounding types. You can configure through the setting dip switch.
Setting methods are shown below.
• Before setting the dip switch, make sure the input power is turned
OFF.
• Use a non-conductive object to set the dip switch.
•
9.2 Power Grid Connection and Grounding
Type
Switch 1 (Power Grid Type)
Switch 2 (Grounding System)
ON
LN
IT
OFF
LL
TT-TN
120V
120V
208V
PE
L1
L2
V/2
V/2
V
PE
L1
L2
0
V
V
PE
L
N
V=240 or 200 volt
Charger
input terminal
Charger
input terminal
Charger
input terminal
V=240 or 230 or 220 or 200 volt
*Note 1: The default value in North America and Japan is (LL / TT-TN).
*Note 2: The default value for other regions is (LN / TT-TN).
*Note 3: If it is not the above standard grid type, please contact our technical staff
for assistance and confirmation.