1 2
9. Installation Instructions
• Read this user manual thoroughly and make sure to review all local
building and electrical codes before installing the AC charger. A
qualified technician should install the AC charger according to the
user manual and local safety regulations.
• Use appropriate protection when connecting to the main power
distribution cable.
• Type B, C or D breaker with a rating current of 60Amp should be
installed in the upstream AC distribution box.
• Disconnect switch for each ungrounded conductor of AC input shall
be provided by others in accordance with the National Electric Code,
ANSI/ NFPA 70.
• Verify that the Wall Connector is properly grounded. The ground
connection must be bonded in the upstream power supply for
proper operation. Check all physical connections, including the
wire box terminals, electrical panel(s), and wire box. In residential
power supplies, check the bond between ground and neutral at the
main panel. If connected to a step- down transformer, contact the
transformer's manufacturer for direction on how to bond the ground
connection.
9.1 Safety Requirements
A
Dip switch
Rotary switch
B
A
B
MC-
AX Series - User Manual
15
Содержание AX Series
Страница 2: ......
Страница 56: ...Manufacturer Contact Info Sticker ...