5-2 

PARTS LIST (continued) 
 

ITEM 

DESCRIPTION 

QTY 

PART NO. 

 

 

 

 

 

ASSY. NO. 7309900500, SECTION 03

 

 

 

 

 

 

 

 

TRANSFORMER, 120V PRI., 6000V SEC., 

1896050 

 

130VA, JEFFERSON ELECTRIC #720-33 

 

 

 

 

 

 

 

CASE 

2100513 

 

 

 

 

 

SMALL TEST LEAD WIRE (RED) 

10

 

 

 

SMALL TEST LEAD WIRE (BLK) 

10

 

 

 

RG8U, OUTPUT LEAD 

10

 

 

 

 

 

 

D9 

DIODE, 40KV, 25MA 

1782010 

 

EDAL INDUSTRIES B412-40-25 

 

 

 

 

 

 

C7,8 

CAP., .05UF, 15KV 

1092565 

 

 

 

 

R35 

RES., 47M, ROX1, 6W, 1% 

1746940 

R36 

RES., 10K, 10W, 10% 

1742190 

R37 

RES., 45M, 6W, 1% 

1746850 

 

 

 

 

 

ASSY. NO. 31116901, SECTION 02

 

 

 

 

 

 

 

PCB1169 

PM6 MAIN PCB# 1169 

1111690 

 

 

 

 

T1 

TRANSFORMER ST-4-24, 24V CT, 120V PRI. 

1894335 

 

 

 

 

K1 

RELAY, 12VDC COIL 

1701035 

K2 

RELAY, 120VAC COIL, 4PDT 

1701300 

 

SOCKET 

1157340 

 

WIRE BALE 

1703350 

 

 

 

 

Q1 

VOLTAGE REG., +12VDC, MC7812CT 

1794005 

Q2 

VOLTAGE REG., -12VDC 

1794006 

Q3 

SCR, C106B1 

1803100 

 

 

 

 

D1-6 

DIODE, 1N4007 (1000VR, 1A) 

1780025 

 

 

 

 

U1, 3 

OP-AMP CA314OE 

1790100 

U2 

OP-AMP COMPARATOR, LM311N 

1794493 

 

 

 

 

Z 1, Z3 

MOVISTOR 35V 

1606130 

Z2 

TRANSORB, 10V, IN6273A 

1780063 

C1 

CAP. .27UF, 50V 

1093175 

C2 

CAP. 10 UF, 20 VDC TANT. 

1095800 

C,3,9,11,12 

CAP. .01UF, 1 kV 

1092050 

C4,5 

CAP. 470UF, 35VDC 

1098470 

C6,10 

CAP. 10UF, 25VDC 

1095825 

 
 

Содержание PM6

Страница 1: ...OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 1 0...

Страница 2: ......

Страница 3: ...N NOTES DESCRIPTION SPECIFICATIONS CONTROLS AND CONNECTIONS 2 FRONT PANEL CONTROLS AND METERS INPUT OUTPUT CONNECTIONS INSTALLATION AND OPERATION INSTRUCTIONS 3 INSTALLATION OPERATION TEST LEAD CONNEC...

Страница 4: ...e Test Equipment have been listed below for your reference Become familiar with your instrument before performing an actual test Know your work area check that all circuits are de energized and locked...

Страница 5: ...to keep non essential personnel away from the test site 7 When testing cables the conductors at the distant end should be isolated from each other and taped 8 When testing a faulted cable it is advisa...

Страница 6: ...f motors cables and transformers Input 120 Volts AC 50 60 Hz single phase 3 Amps or 220 Volts AC 50 60 Hz single phase 15 Amps Output 0 6 kV DC continuously adjustable with manual control Negative Out...

Страница 7: ...meter The currentmeter range is selected by the five position rotary switch The switch setting indicates the full scale current of the currentmeter and the megohmmeter multiplier The table below shows...

Страница 8: ...highest level full clockwise approximately 110 of full scale current will be allowed At its lowest level full counterclockwise approximately 10 of full scale current will be allowed before shutdown I...

Страница 9: ...IONS continued AC Line This cord supplies input power to the tester Output This test lead with clip and insulation boot supplies the testers output to the apparatus under test Fuse If this protective...

Страница 10: ...pressing the Power switch The switch will illuminate and remain recessed 2 Energize the High Voltage power supply by pressing the High Voltage power switch The switch will illuminate and remain recess...

Страница 11: ...reading must be multiplied by 4 Similarly if a test voltage of 1 kV is used on the 5 kV scale the corresponding upper megohm scale reading and range multiplier result must be multiplied by 2 NOTE Be...

Страница 12: ...meter 3 Any current flowing through the test lead attached to the Guard terminal on the tester will never be measured by the DC Microammeter 4 Current flowing through the test lead attached to the Gro...

Страница 13: ...nal to the Test Set depending on the design Nothing is connected to the Guard Both stray leakage to earth ground and leakage through the Test Specimen is indicated on the current meter This configurat...

Страница 14: ...ed on the current meter Any current associated with the Guard bypasses the current meter Leakage current through the test specimen is indicated on the current meter Stray leakage to earth ground is no...

Страница 15: ...4 1 SCHEMATIC Drawing Number Description 01 P124 PM6...

Страница 16: ......

Страница 17: ...0 LABEL HV ON 1 PROTECTIVE GROMMET 1 SW3 SW4 SWITCH ROTARY 2 POLE 2 1863047 KNOB FOR ROTARY SWITCH 2 1355310 R23 POT 10K SENSITIVITY ADJ 1 1761092 KNOB FOR ABOVE POT 1355305 ASSY NO 7209900500 SECTION...

Страница 18: ...1116901 SECTION 02 PCB1169 PM6 MAIN PCB 1169 1 1111690 T1 TRANSFORMER ST 4 24 24V CT 120V PRI 1 1894335 K1 RELAY 12VDC COIL 1 1701035 K2 RELAY 120VAC COIL 4PDT 1 1701300 SOCKET 1 1157340 WIRE BALE 1 1...

Страница 19: ...1 1712405 R23 RES 1 5M 1 4W 1 1 1735140 R10 11 33 39 RES 1K 1 1 4W MF 4 1722082 R15 100 OHM 1 4W 1 2 1720180 R19 RES 14 5K 5W 1 1 1722200 R24 22K 1 4W 1 MF 1 1722587 R25 RES 110K 1 4W 1 MF 1 1734110 R...

Страница 20: ...g parts to include the serial number of the unit as well as the part number of the replacement part When your purchase order is received at our office a representative of Phenix Technologies will cont...

Страница 21: ...for Return Cause of Defect If Phenix Technologies Inc deems return of the part appropriate it will then issue an Authorization for Return If return is not deemed advisable other inspection arrangement...

Отзывы: