4
CABLING ADVICE
WHAT IS THE BEST TYPE OF CABLE TO USE?
You can use Cat5e, Cat6, Cat6A or Cat7 with this system.
The minimum cable standard for this system is Cat5e. Slightly greater distances may be achieved by using Cat6A,
or slightly better still with Cat7, which has stricter shielding requirements and reduces potential cross talk between
data pairs.
Whichever network cable type you choose, ensure that the main wiring architecture is solid core, not stranded
patch cabling. Patch cabling can be used for the last few metres of a run (e.g. from a wall plate) but must be avoided
over longer runs as signal transfer over stranded cores is heavily reduced.
The use of pre-made leads is not recommended unless you can be absolutely sure of their construction credentials
(i.e. solid core 568B). Please note that CCA (Copper Clad Aluminium) cable is NOT supported.
SHIELDED CABLES
Unlike other systems, shielded FTP cable is not a stipulation. If, however, you prefer this type of cable please ensure
compatible shielded accessories are used. Failure to terminate cable screen at all points can induce interference
rather than eliminating it.
CABLING BEST PRACTICE
Our best practice policy is to terminate to a wall plate at either end and then use solid core patch cables (usually
it is better to make your own than use pre-made) between the patch panel and the matrix and the wall plate and
HDBaseT™ receiver.
HDBaseT™ WITH PATCH PANELS AND WALL PLATES
If the patch panels are terminated correctly, there is minimal loss of distance. The use of wall plates and patch
panels, however, has the potential to cause increased resistance on the cable if not done correctly, introducing
pinch points for signal transmission, and could reduce advertised transmission lengths.
Instead of using RJ45 wall plates, you can use brush plates to maintain the neat finish.
CONNECTION TERMINATION
Terminate the cabling using RJ45 connectors to the 568B wiring standard. (See diagram)
IMPORTANT
Please note that local building regulations may apply to the installation of cabling in
properties. It is important to check building regulations to guarantee that you are in
accordance with the laws of your territory.