      SPECIFICATIONS

 

 

Product name 

Biomedical Freezer 

MDF-MU339 

Biomedical Freezer 

MDF-MU539 

External dimensions 

W616 mm x D770 mm x H1802 mm 

W793 mm x D770 mm x H1802 mm 

Internal dimensions 

W472 mm x D614 mm x H1262 mm 

W649 mm x D614 mm x H1262 mm 

Effective capacity 

369 L 

504 L 

Exterior 

Painted steel 

Interior 

Painted steel 

Insulation 

Rigid polyurethane foamed-in place 

Outer door 

Painted steel 

Shelf 

Made of hard steel wire + PE coating : 6 pcs   

Load; 30 kg/shelf 

Evaporator 

Tube on sheet type (Liner combined use) 

Access port 

Diameter 30 mm, 1 on back side 

Condenser 

Wire and tube type   

Compressor 

Hermetic type, 250 W   

Refrigerant 

R-404A 

Temperature controller 

Microcomputer control system 

Temperature display 

Digital display (between -50 

o

C and +50 

o

C) 

Temperature sensor 

Thermistor sensor 

Temperature alarm 

Flash of digital temperature indicator and alarm lamp, Buzzer, (Remote alarm) 

Remote alarm contact 

Allowable contact capacity: DC 30 V, 2 A *1 

Accessories 

Key 1 set, Defrost spatula 1 pc 

Storage container : 6 pcs 

Storage container : 12 pcs 

Weight 

135 kg 

163 kg 

Battery 

For power failure alarm, Nickel-metal-hydride battery, 

DC 6 V, 1100 mAh, Automatic charge 

Optional component 

Temperature recorder (MTR-G85C)+Recorder fixing (MPR-S7), 

Temperature recorder (MTR- Recorder fixing (MPR-S30) 

Interface board (MTR-480, MTR-L03) *1, *2 

   

*1

It is recommended to use standard signal and interface cables with a maximum length of 30 meters. 

*2

:

 For the data acquisition system MTR-5000 user only. Contact our sales representative or agent for purchase. 

 

  Note: 

• Design or specifications are subject to change without notice. 
• Refer to the updated catalogue when ordering an optional component. 

 
 
 
 
 

 
 
 
 

Содержание MDF-MU339

Страница 1: ...MU539 MDF MU539 Please read the operating instructions carefully before using this product and keep the operating instructions for future use See page 35 for model number Operating Instructions Biome...

Страница 2: ...UZZER INTERLOCK MODE 21 CHANGE OF COMPRESSOR DELAY TIME 22 DURING AFTER POWER FAILURE 23 REMOTE ALARM TERMINAL 23 ALARMS SAFETY FUNCTIONS 24 ROUTINE MAINTENANCE 25 Cleaning the exterior interior and a...

Страница 3: ...t notice for improvement of performance or function Contact our sales representative or agent if any page of the operating instructions is lost or the page order is incorrect or if the instructions ar...

Страница 4: ...are illustrated in the following way WARNING Warning indicates a potentially hazardous situation which if not avoided could result in serious injury or death CAUTION Failure to observe CAUTION signs...

Страница 5: ...re flammable or volatile substances are present may cause explosions and or a fire Do not install the unit in a location where corrosive gases such as acids are present Installing the unit in a locati...

Страница 6: ...if the liquid is spilled Never damage the power supply cord or power supply plug by breaking adapting placing near a source of heat bending with force twisting pulling adding weight or binding A dama...

Страница 7: ...y out disassembly and disposal of the unit Leaving the unit in a location that can be accessed by third parties may result in unexpected accidents e g the unit may be used for unintended purposes Do n...

Страница 8: ...or alkalis in this unit except in a sealed container These may be harmful to your health and may cause corrosion of internal components or electrical parts Check the settings when restarting operatio...

Страница 9: ...l indicates an earth ENVIRONMENTAL CONDITIONS This equipment is designed to be safe at least under the following conditions based on the IEC 61010 1 Indoor use Altitude up to 2000 m Ambient temperatur...

Страница 10: ...ONENTS Back side Space for interface board MDF MU539 9 13 MDF MU339 11 10 14 Right side 4 8 7 12 6 5 3 1 2 Drain port Bottom of cabinet 4 3 8 1 2 6 5 7 Drain port Bottom of cabinet Storage contaner St...

Страница 11: ...latch To lock the outer door turn this latch downward To unlock rotate this latch up A padlock is also available 8 Control panel To display the temperature setting and running condition See page 12 9...

Страница 12: ...ing this key for more than 5 seconds in the temperature display mode 5 Set key SET Temperature setting mode is led by pressing this key Once the key is pressed the changeable digit is flashed Pressing...

Страница 13: ...possible to achieve a stable cooling performance The ambient temperature to use is 5 o C degrees to 35 o C degrees for MDF MU339 5 o C degrees to 30 o C degrees for MDF MU539 A flat surface where the...

Страница 14: ...ng the unit using the levelling feet Rotate the front levelling feet clockwise until the casters are raised 5 mm to 10 mm above the floor surface Fig 1 In addition rotate the levelling feet slightly c...

Страница 15: ...together in the chamber Fix the shelves on the shelf stoppers securely before start up of the unit Incomplete installation may cause injury or damage The shelf stoppers are attached to the standard lo...

Страница 16: ...larm test key ALARM TEST The remote alarm is also operated E09 is displayed on the digital temperature indicator and buzzer sounds if the battery switch is off Make sure to turn on the battery switch...

Страница 17: ...guaranteed temperature is 30 C at no load The setting mode returns to the temperature display mode automatically when 90 seconds has passed without any key operation In this case any setting before p...

Страница 18: ...changes 4 Press set key SET The current setting is displayed and the first digit is flashed 5 Set the figure to 005 by using digit shift key and numerical value shift key When pressed the settable di...

Страница 19: ...rical value shift key for 5 seconds The display changes to F00 and the first digit blinks 3 Set the figure to F50 by using digit shift key and numerical value shift key When pressed the settable digit...

Страница 20: ...it shift key for 5 seconds The display changes to F00 and the first digit blinks 3 Set the figure to F25 by using digit shift key and numerical value shift key When pressed the settable digit is shift...

Страница 21: ...l value shift key for 5 seconds The display changes to F00 and the first digit blinks 3 Set the figure to F24 by using digit shift key and numerical value shift key When pressed the settable digit is...

Страница 22: ...es Description of operation Key operated Indication after operation 1 The current chamber temperature is displayed 2 Press numerical value shift key for 5 seconds The display changes to F00 and the fi...

Страница 23: ...ture then the high temperature alarm is activated and the buzzer sounds and the remote alarm is also activated Please push the buzzer stop key BUZZER to silence buzzer and take appropriate actions if...

Страница 24: ...nser sensor is disconnected Alarm lamp is flashed E03 and chamber temp are displayed alternately Intermittent tone Remote alarm If the condenser sensor is short circuited Alarm lamp is flashed E04 and...

Страница 25: ...roduct is refrigerated by the direct cooling When it uses for a long time frost appears on the chamber wall It cannot be cooled down when there is much amount of frost The defrost is mentioned in the...

Страница 26: ...buzzer sound as a result of power from the battery for the power failure alarm The regular replacement of the battery for the power failure alarm is important to prevent an increase in chamber temper...

Страница 27: ...rature load have been put in the chamber The door is open No key operation is available The key lock is set in ON L 1 Set the key lock in OFF L 0 During setting mode the mode returns to temperature di...

Страница 28: ...bliged to comply with Japanese battery regulation Label indication is obliged to comply with Taiwanese battery regulation Refrigerant REGULATION EU No 517 2014 on Certain Fluorinated Greenhouse Gases...

Страница 29: ...z s megakad lyozza az emberi eg szs g s a k rnyezet k rosod s t Amennyiben a begy jt ssel s jrafelhaszn l ssal kapcsolatban tov bbi k rd se lenne k rj k rdekl dj n a helyi nkorm nyzatn l E hullad kok...

Страница 30: ...cycling gem den gesetzlichen Bestimmungen den zust ndigen Sammelpunkten zu Endnutzer sind in Deutschland gesetzlich zur R ckgabe von Altbatterien an einer geeigneten Annahmestelle verpflichtet Batteri...

Страница 31: ...med almindeligt husholdningsaffald For korrekt behandling indsamling og genbrug af gamle produkter og batterier skal du tage dem til indsamlingssteder i overensstemmelse med den nationale lovgivning...

Страница 32: ...weg te gooien helpt u mee met het besparen van kostbare hulpbronnen en voorkomt u potenti le negatieve effecten op de volksgezondheid en het milieu Voor meer informatie over inzameling en recycling ku...

Страница 33: ...resentative or agent For the usage of the temperature recorder also refer to an installation sheet enclosed with the temperature recorder Main specifications of temperature recorder MTR G85C MTR 4015L...

Страница 34: ...50 o C and 50 o C Temperature sensor Thermistor sensor Temperature alarm Flash of digital temperature indicator and alarm lamp Buzzer Remote alarm Remote alarm contact Allowable contact capacity DC 3...

Страница 35: ...rature 5 o C to 35 o C Humidity equal or less than 80 R H The unit with CE mark complies with EU directives Product name Biomedical Freezer MDF MU539 Model number MDF MU539 PE Cooling performance 30 o...

Страница 36: ...the unit Unit interior No contamination Decontaminated Contaminated Others 3 Instructions for safe repair maintenance disposal of the unit a The unit is safe to work on b There is some danger see bel...

Страница 37: ...37 MEMO...

Страница 38: ...38 MEMO...

Страница 39: ...39 MEMO...

Страница 40: ...Printed in Indonesia LDCL045400 2 N0418 20619 PHC Corporation 2018 1 1 1 Sakada Oizumi machi Ora gun Gunma 370 0596 Japan...

Отзывы: