Phcbi MBR-305GR Скачать руководство пользователя страница 11

 

9

 

   REFRIGERATOR COMPONENTS 

 

1.

 

Door alarm switch: 

This switch detects the door status (open/close).  The door check lamp is ON 

when the door is open and the alarm buzzer sounds with 2 minutes delay. [page 19] 

 

2.

 

Battery switch: 

ON-OFF switch for built-in battery for power failure alarm.    Always turn on this switch 

when the refrigerator is operated to assure the power failure alarm.  Turn off this switch when the 
refrigerator is not used for long period to protect the battery. 

 

3. Control panel: 

With the key on the control panel, temperature display can be changed and the alarm 

test is available.    Also, the running status can be checked on the temperature display and an indicator. 
[page 10] 

 

4.

 

Air intake vent (upper front): 

Do not block this vent.  Blocking this vent may cause unstable 

chamber temperature.    Do not insert fingers or similar articles into the vent. 

 

5.

 

Inner door: 

This prevents the cold air from escaping when the outer door is opened.    Always close 

the inner door surely before closing the outer door. 

 

6.

 

Air exhaust vent (bottom front): 

Do not block this vent.  Blocking this vent may cause unstable 

chamber temperature.  Arrange the storage items not to subject to the cold air from this vent. 

 

7. Leveling feet (front, 2 locations): 

These are screw bolts used to install and fix the unit.    Adjust the 

height of the leveling feet by turning the screw bolts until 2 front casters are away from the floor.

 

[page 12] 

 

8.

 

Dew receiver: 

The condensation on the outer door is accumulated on this dew receiver.    Wipe off the 

water on the dew receiver with a cloth. 

 

9. Monitor bottle (upper and lower): 

A sensor to display the chamber temperature is attached to the 

monitor bottle.  Fill the bottle with 200 mL of 10 % glycerol fluid or water before commencing the 
operation. [page 15] 

 

10.

 

Drawer: 

The maximum load is 20 kg per drawer.

 

 Items to be stored in the chamber must be placed on the shelves or drawers.  Do not put storage 

items directly on the bottom of the chamber. 

 

11. Access port (left side): 

This port allows a sensor or cable of measuring equipment to enter the 

chamber from outside. 

 Replace the insulation and the rubber caps when the access port is not used.    Improper replacement 

may cause rise of chamber temperature or condensation around the access port. 

 

Содержание MBR-305GR

Страница 1: ...ries Please read the operating instructions carefully before using this product and keep the operating instructions for future use See page 32 for all model numbers Operating Instructions Blood Bank R...

Страница 2: ......

Страница 3: ...R TEMPERATURE P 16 DEFROSTING OF EVAPORATOR P 16 REMOTE ALARM TERMINAL P 17 CALIBRATION OF SENSOR P 18 ALARM FUNCTIONS P 19 SELF DIAGNOSTIC FUNCTIONS P 20 ROUTINE MAINTENANCE Cleaning of exterior inte...

Страница 4: ...provement of performance or functions Contact our sales representative or agent if any page of the operating instructions is lost or page order is incorrect Contact our sales representative or agent i...

Страница 5: ...t in a hazard to personnel possibly resulting in serious injury or death CAUTION Failure to observe CAUTION signs could result in injury to personnel and damage to the unit and associated property Sym...

Страница 6: ...wer supply outlet is not grounded it will be necessary to install a ground by qualified engineers Never ground the unit through a gas pipe water main telephone line or lightning rod Such grounding may...

Страница 7: ...al operation may cause electric shock or fire When removing the plug from the power supply outlet grip the power supply plug not the cord Pulling the cord may result in electric shock or fire by short...

Страница 8: ...r improper insertion may cause a heat or ignition Never store corrosive substances such as acid or alkali in this unit if the container cannot be sealed These may cause corrosion of inner components o...

Страница 9: ...C Maximum relative humidity 80 for temperature up to 31 o C decreasing linearly to 50 relative humidity at 40 o C Mains supply voltage fluctuations up to 10 of the nominal voltage Transient overvoltag...

Страница 10: ...8 REFRIGERATOR COMPONENTS Refrigerator unit 7 1 Florescent lamp page 22 Temperature recorder Light switch 2 3 4 5 6 8 10 11 9 Glow starter page 23 Power switch Door gasket 9...

Страница 11: ...ent bottom front Do not block this vent Blocking this vent may cause unstable chamber temperature Arrange the storage items not to subject to the cold air from this vent 7 Leveling feet front 2 locati...

Страница 12: ...n error code and a chamber temperature is displayed alternately when the self diagnostic function detects any abnormality page 20 6 Up arrow key This key is used at calibration mode of sensor for temp...

Страница 13: ...stall the unit on a sturdy and level floor withstanding the total weight of the unit The uneven floor or tilted installation may cause failure or injury Unstable condition may cause vibration or noise...

Страница 14: ...ounterclockwise to separate 2 front casters from the floor Fig 1 And adjust the leveling foot to level the unit The unit is installed firmly by separating the front casters from the floor The unit may...

Страница 15: ...e than 2 minutes The alarm buzzer is canceled when the outer door is closed 3 The chamber temperature is set to 4 o C at the factory Check that the chamber temperature reaches 4 o C on the temperature...

Страница 16: ...xhaust by the storage items near the air exhaust vent Care should be taken not to put storage items nearby the air exhaust vent The storage items may be frozen Load line The storage area is limited to...

Страница 17: ...herefore it is removed together with the cover Take out the recorder sensor as well from the lower monitor bottle 4 Remove the fixing screws 2 screws and take out the monitor bottle 5 Remove the cap s...

Страница 18: ...temperature display changeover key Lower temperature is displayed UPPER LOWER Lower temperature 4 Press the temperature display changeover key Mean temperature is displayed UPPER LOWER Mean temperatu...

Страница 19: ...is canceled by pressing the alarm buzzer stop key BUZZER since the remote alarm terminal is operated in conjunction with alarm buzzer However the alarm status of remote alarm terminal is not canceled...

Страница 20: ...ting the mixture allow the temperature indicated on the temperature display to be stable 7 Calibration is needed if the temperature on the temperature display does not show 0o C 8 Press the calibratio...

Страница 21: ...However the alarm status of remote alarm terminal is not canceled by pressing the alarm buzzer stop key BUZZER when the unit is under power failure alarm This unit is provided with the alarm buzzer re...

Страница 22: ...and chamber temp is displayed alternately If the upper sensor for temp display is short circuited Alarm indicator blinks E16 and chamber temp is displayed alternately If the lower sensor for temp disp...

Страница 23: ...t cloth Then wipe off the cabinet or accessories with a dry cloth Important Never pour water onto or into the unit This may cause electric shock or failure CAUTION Do not use a brush an acid a thinner...

Страница 24: ...e clip 2 locations together with the wiring Fig 1 4 After removing the water proof cover remove the socket with the wiring on the both sides of the lamp cover Fig 2 5 Take out the fluorescent lamp fro...

Страница 25: ...Turn off the light switch and power switch and then disconnect the power supply plug 2 Remove the glow starter and install a new glow starter glow starter FG 1P 3 Connect the power supply plug to the...

Страница 26: ...lacement of the battery for power failure alarm involves the risk of electric shock Important The used battery is a recyclable precious resource Do not dispose of the battery Always follow the procedu...

Страница 27: ...breaker on the supply circuit is activated A breaker of 15 A or more is recommended The fuse on the supply circuit is blown The outer door was kept opened for a long time The outer door is opened An e...

Страница 28: ...ersonnel Always remove doors to prevent accidents such as suffocation Recycle of battery The unit contains a rechargeable battery The battery is recyclable At the end of its useful life check with you...

Страница 29: ...the chemical involved German Entsorgung von Altger ten und Batterien Nur f r die Europ ische Union und L nder mit Recyclingsystemen Dieses Symbol auf den Produkten der Verpackung und oder den Begleitd...

Страница 30: ...r sur les piles pictogramme du bas Si ce pictogramme est combin avec un symbole chimique il r pond galement aux exigences pos es par la Directive relative au produit chimique concern Spanish Eliminaci...

Страница 31: ...Neste caso estar em conformidade com o estabelecido na Diretiva referente aos produtos qu micos em causa Italian Smaltimento di vecchie apparecchiature e batterie usate Solo per Unione Europea e Nazi...

Страница 32: ...l Onderstaand symbool Dit symbool kan in combinatie met een chemisch symbool gebruikt worden In dit geval volstaan de eisen die zijn vastgesteld in de richtlijnen van de desbetreffende chemische stof...

Страница 33: ...r Fin and tube type Condenser Wire and tube type Refrigerant R 134a Defrosting Cycle defrost forced defrost Fully automatic Defrost heater 50 W Temperature controller Electronic control system Tempera...

Страница 34: ...o C to 35 o C Noise level 41 41 dB A scale 50 Hz 60 Hz Maximum pressure 1850 kPa Rated voltage AC 115 V AC 220 V AC 220 V Rated frequency 60 Hz 60 Hz 60 Hz Amperage 3 0 A 1 7 A 1 5 A Power consumption...

Страница 35: ...Contamination of the unit Unit interior No contamination Yes No Decontaminated Yes No Contaminated Yes No Others 3 Instructions for safe repair maintenance disposal of the unit a The unit is safe to...

Страница 36: ...ginal Operating Instructions Printed in Japan LDCL038300 0 S0418 0 2018 04 01 1 1 1 Sakada Oizumi machi Ora gun Gunma 370 0596 Japan PHC Corporation 2018 Nijverheidsweg 120 4879 AZ Etten Leur The Neth...

Отзывы: