Heat/cool stage furnace-power
Connect Stage 3 to terminals 30 and 31.
A -
Relay Ratings: 6 A at 120/230 VAC, general-purpose
(resistive)
1/3 HP at 120 VAC, 1/2 HP at 230 VAC
360 W tungsten at 120 VAC
Fuse 12 A, 250 VAC ABC-type ceramic
B -
This configuration shows the TVS connected to the
power connections for a gas fired furnace or brooder.
Heat/cool stage furnace-thermostat
Connect Stage 3 to terminals 30 and 31.
A -
Relay Ratings: 6 A at 120/230 VAC, general-purpose
(resistive)
1/3 HP at 120 VAC, 1/2 HP at 230 VAC
360 W tungsten at 120 VAC
Fuse 12 A, 250 VAC ABC-type ceramic
B -
In this configuration the TVS is connected to the
thermostat inputs for a gas fired furnace or brooder.
10245506
35