Phason
31 / 98
34740001
Configuring relays
Supra Touch has 12 relays that can be configured for any of the following functions:
Unassigned
: the relay is always open/off. This is the default.
Cooling
: the relay controls cooling equipment, such as a fan, and switches on when temperatures are
above the set point.
Cooling duty cycle
: the relay controls cooling equipment and switches on and then off for specified
durations when temperatures are above the set point.
Heating
: the relay controls heating equipment, such as an electric heater, and switches on when
temperatures are below the set point.
Heating duty cycle
the relay controls heating equipment and switches on and then off for specified
durations when temperatures are below the set point.
Follow relay / variable
: the relay controls equipment that is on when a selected relay or variable stage is
on.
To configure relays
1.
Press the
Menu
and then
Configuration
.
2.
Press
Equipment
.
3.
Press
Relays
.
4.
Press the relay you want to configure.
The Equipment Configuration screen displays.
Name:
a)
Press the button beside Name and then press
Rename
.
b)
Press
Reset
and then type the new name.
c)
When finished, press
Confirm
to save the name and return to the previous screen.
Function:
Press the button beside Function and then choose the equipment type. If you choose
“relay
follower” or “variable follower”, you will need to press
Following
and then choose the output that
the relay will follow.
Zone:
Press the button beside Zone and then choose the one the equipment will operate in.
5.
Press
Save
when you are finished.
Name
Function
Zone