To connect a normally open alarm system
If you are connecting an alarm system with a normally open connection,
meaning it closes when there is an alarm, connect it as shown in the
normally open diagram.
If you are connecting the alarm system to more than one Supra Touch,
join all the
CC
connections together and all the
OA
connections together.
The alarm relays must be in parallel with each other so any of the
controls can trigger the alarm system when an alarm occurs.
To connect a normally closed alarm system
If you are connecting an alarm system with a normally closed
connection, meaning it opens when there is an alarm, connect it as
shown in the normally closed diagram.
If you are connecting the alarm system to more than one Supra Touch,
join the alarm relays in a continuous loop. The alarm relays must be in
series with each other so any of the controls can trigger the alarm system
when an alarm occurs.
Connecting sensors
Supra Touch gives you the ability to monitor more than just zone temperatures. Connecting additional
sensors gives you the ability to use modifiers that allow you to override settings when certain conditions are
met, such as when carbon dioxide levels are too high. For more information, read
The following table shows the conditions you can monitor, the number of inputs, and the compatible
sensors.
Condition
Inputs
Sensor
Zone temperature
4
Phason 3K Series
Outdoor temperature
1
Phason 3K Series
Humidity
1
Phason RHS or RHS-P
Wind speed
1
Phason WINDSPEED-03
Water flow / usage
Any water meter with a dry contact pulse output
Additional temperature and humidity
1
DOL 114
Carbon dioxide (CO2)
3
DOL 19
Ammonia (NH3)
DOL 53
Light
DOL 16