For information about growth curves, read
From information about minimum ventilation curves, read
To configure zone control
1.
Press the
Menu
and then
Configuration
.
2.
Press
Zone Control Mode
.
3.
For each zone you are configuring, choose
Staged
or
Merged
ventilation.
4.
If you will be using a growth curve and/or minimum ventilation curve (staged only), press the checkbox
beside that option.
5.
Press
Save
when you are finished.
Configuring sensor inputs
Supra Touch supports the following sensors connected to the specified inputs. Others are not supported.
Input
Location
Sensor types
Zone control
Influencer
TEMP1 to 4
Bottom
Phason 3K Series
YES
YES
TEMP
HUM
Cover
DOL 114 Temperature and Humidity Sensor
TEMP
–
YES
HUM
–
NO
YES
AUX1
AUX2
AUX2
Cover
DOL 19 Carbon Dioxide (CO2)
DOL 53 Ammonia Sensor (NH3)
DOL 16 Light Sensor
NO
YES
OUT TEMP
Bottom
Phason 3K Series
NO
YES
COUNT
Cover
Phason Wind Speed Sensor, water meter
NO
YES
For the exact location of the sensor inputs, see the diagrams on pages 11 and 12.