background image

iWire Flex Radio installation guide 

Phason 

 

 

33841000 

iWire range 

iWire Radios have an outdoor, line-of-sight range of up to 5 miles, and an indoor range of up to 500 
feet. Range can vary depending on obstacles, building structure, or interference from other electrical 
devices. 

 

iWire layout 

 

 

 

Mode switches (S1, S2, MDE) 

Set all three mode switches in the

 UP 

position to 

configure the radio as a 

MASTER

.

 

 

 

 

Set the switches in the 

DOWN

 position to  

configure the radio as a 

REMOTE

 

 

Channel switches (CH0 to CH6)

 

Make sure the channel switch positions on the MASTER 

match the switch positions on all REMOTES. 

 

 

Termination jumpers (J1, J2)

 

 

Make sure the shunts are on a single pin.  

 

 

 

Outdoor temperature probe connection (when connected to the PCH only) 

If you have the iWire Flex connected to a Phason Communication Hub, you can connect a Phason temperature probe 

for reading outdoor temperatures in OMNI Select. For more information, read 

Connecting a temperature probe

 on 

page 4. 

 

 

 

 