15
Curtain machines
Curtains are usually controlled by equipment called curtain machines (sometimes referred to as
winches). Curtains are opened and closed to let in more air or less air, the idea being more air cools
the building. Curtain machines use a timer and do not have a feedback potentiometer.
To connect actuators
1.
Connect actuators to the control as shown below. Refer to your
actuator’s
installation guide for
information about its power supply requirements.
2.
Calibrate the actuator. You can calibrate by pressing the CALIBRATE button, or using the
display. For more information the calibration process, and instructions for calibrating using the
display, read
AC powered actuators
DC powered actuators
When routing the actuator feedback wires, do not run them in or along the
same conduit as AC-power lines.
If you are unsure of the potentiometer wiring for your actuator, read
Determining correct actuator feedback wiring
If you are measuring AC power with a digital multimeter (DMM) and a limit
switch opens the circuit, the DMM measures voltage after the relay switch even
if the relay is open.