5.9 Manage Contacts 

 
Alerts  can  be  customized  to  text  or  email  contacts  when  an  event  of  interest  occurs. 

Manage Contacts

  is found  in the  Portal  Navigation  Pane.  Contacts  can  be  arranged  into 

groups  that  can  receive  alert  notifications.  Use  this  to  save  time  when  setting  up  alert 
notifications if multiple contacts need to be notified. 

 
 

5.10 Adding New Users to Account 

 

Additional  users  can  be  added  to  accounts  from  the 

Manage  Users

  page,  found  in  the 

Portal  Navigation  Pane,  on  the  left  edge  of  the  screen.  Click  “Add  User”  in  the  top  right 
corner,  enter  the  new  user’s  name  and  email,  and then  select  their 

Role

.  Their  Role  will 

determine  their  permission  structure.  Administrators  are  the  only  users  that  can  view  and 
update billing information. Se

Table 5

, below for a description of each Role. 

 

Table 5

 

– User Roles 

Role 

Description 

Administrator 

Has all the same permissions as User with Control. Can view and 
edit payment information and add device users. 

User with Control 

Can view device readings, make changes, acknowledge alerts, and 
create new alerts. 

View Only 

Can view device readings but cannot make changes. Can 
acknowledge alerts. 

 

5.11 Removing Users from Account 

 

To remove a user from an account, go to the 

Manage Users

 page, in the Portal Navigation 

Pane, and click on the user that you wish to remove from the account. Click 

Unlink User

 to 

revoke  their  portal  access.  The  user  will  then  receive  an  email  notification  that  they  have 
been removed from the account. 
 
 

5.12 Transferring Account 

 

To transfer ownership of the account to another user, go to the 

Manage Users

 page in the 

Portal  Navigation  Pane.  Click  the 

Add  User

 

button and enter the new owner’s name and 

email address, ensure the 

Role

 is set to Administrator and click the 

Add

 button. 

 
The new user will receive an email with their login credentials. Once the new user is logged 
in,  they  can  go  to  the 

Manage  Users

 

page,  click  on  the  old  owner’s  name,  and  select 

Unlink User

. If the original device owner cannot be reached to transfer device ownership, 

contact Phase Technologies for assistance. 
 
 

5.13 Pausing Device Communication 

 

Helpful Tip 

Pausing device communication will still incur subscription charges.

 

 
Pausing a device will stop all communication between the device and the online portal, but 
subscription  costs  will  still  be  charged.  If  a  device  has  been  paused  through  the  portal, 

Содержание PHASE CONNECT PC4R

Страница 1: ...llation Operation Manual http www phasetechnologies com downloads REMOTE EQUIPMENT MANAGEMENT Stay informed from anywhere Intuitive web mobile portal Programmable e mail and text alerts Accepts 100 48...

Страница 2: ...of this publication or its contents may be duplicated by any means electronic or otherwise without the express written consent of Phase Technologies LLC V1 0_06012021 REMOTE EQUIPMENT MANAGEMENT 222...

Страница 3: ...that can create a potentially hazardous situation Electric shock could result in serious injury or death This device should be installed only by trained licensed and qualified personnel Follow instruc...

Страница 4: ...ESET VFD FAULT 9 3 6 4 20 MA OUTPUT CONTROL 10 3 7 REPEAT 4 20 MA INPUT SIGNAL 11 4 1 INITIALIZATION 12 4 2 DEVICE PARAMETERS 12 5 1 CREATING AN ACCOUNT 13 5 2 ACTIVATING A NEW DEVICE 13 5 3 NAVIGATIN...

Страница 5: ...portal users can monitor three inputs one analog two digital and control three outputs one analog two digital Alerts can be customized to send text and or email notifications to one or multiple contac...

Страница 6: ...Input Voltage 90 VAC 528 VAC Input Current 3 A Operating Temperature Range 10 C to 50 C 14 F to 122 F Storage Temperature 20 C to 60 C 4 F to 140 F Dimensions H x W x D 11 73 x 9 07 x 6 22 Enclosure T...

Страница 7: ...ould be mounted to a solid non flammable surface using the mounting brackets provided It should be installed in a location free from Corrosive gases or liquids Excessive vibration Airborne metallic pa...

Страница 8: ...vice Properly ground the system according to local electrical code Connect the ground terminal to the branch circuit or service ground conductor with an adequately sized conductor according to local e...

Страница 9: ...rranty Table 1 Input Power Terminal Specifications Rating Wire Size Torque Input Power L1 L2 480 V 3 A 18 6 AWG 10 5 lb in Figure 4 Input Power Terminal Locations 2 5 Cable and Wire Routing All cables...

Страница 10: ...ay 1 24 VDC or 277 VAC 12 A Normally open relay controlled via online portal COM1 Common 1 Common terminal for NC1 and NO1 terminals NC1 Normally Closed Relay 1 Normally closed relay controlled via on...

Страница 11: ...e to make sure your VFD settings are set up properly for the chosen operation 3 2 Monitor VFD Run Status To set up the device to detect when a Phase Technologies VFD is running a load connect wires as...

Страница 12: ...ge and units for the transducer being used If the value shown for 4 20 mA Input does not match a manual reading use 4 20 mA Input Offset on the web portal to calibrate Figure 7 Monitor 4 20 mA Input I...

Страница 13: ...ves have this feature Navigate to the AUX SELECT parameters in your drive to ensure it has this ability Some faults on Phase Technologies VFDs require manually cycling incoming power to reset To do th...

Страница 14: ...input The wires connected to AUX 1 and COM of the VFD are used to provide RUN STOP commands from the portal If the VFD is in AUTO mode and the proper settings are selected a RUN command will prompt t...

Страница 15: ...ucer VFD and Phase Connect as shown in Figure 12 On the portal dashboard check the box under the 4 20 mA Output that says Match Input and hit Send Commands Now both the portal and the VFD will read th...

Страница 16: ...blink when connected and be always on when unconnected 4 2 Device Parameters After device is connected parameters and their values will scroll across the display See Figure 13 and Table 4 to understa...

Страница 17: ...s you will need to click on the Activate New Device button on the View Devices page and follow the steps You will need to enter the device Serial Number and Activation Code which can be found on a sti...

Страница 18: ...evices page Devices can be viewed by clicking on them This will open the Device Dashboard for the selected device where settings can be monitored and controlled Use the Device Navigation Pane to navig...

Страница 19: ...ngs to reach or move toward their setpoint before updating the portal readings 5 7 Configuring Your Device The Config page allows you to customize the Dashboard labels and the 4 20 mA settings For acc...

Страница 20: ...iew device readings but cannot make changes Can acknowledge alerts 5 11 Removing Users from Account To remove a user from an account go to the Manage Users page in the Portal Navigation Pane and click...

Страница 21: ...button at the bottom of the settings page for the paused device After the device has been un paused on the portal AND power has been cycled OFF and back ON the device will resume communication 5 14 De...

Страница 22: ...alled into Xbee Antenna disconnected Check antenna connection Poor cellular signal Check antenna for damage and good connection Install signal booster to increase signal strength Xbee communication Ch...

Страница 23: ...an Authorized Service Center is the responsibility of the purchaser Return transportation is provided by Phase Technologies 2 Installations must comply with all national and local electrical codes Ex...

Страница 24: ...Scan to download product information 222 Disk Dr Rapid City SD 57701 866 250 7934 Toll Free 605 343 7934 Main www phasetechnologies com...

Отзывы: