2

Phantom boilers use an electronic means built into the ignition system to extinguish the burner in the event that flames exit 

3. 

the combustion chamber. If the boiler fails to fire, call a qualified gas service technician to diagnose and correct the problem.
Phantom boilers are equipped with a safety feature which will shut down the burner in the event that there is a blockage in 

4. 

the vent system. In the event that the boiler fails to function, and the boiler is vented through an outside wall accessible from 

the ground, inspect the vent terminal on the outside wall for a blockage such as a bee’s nest or ice. If a blockage is found, the 

burner should ignite approximately 30 seconds after the blockage is removed. If no blockage is found, or if the terminal is 

inaccessible from the ground, the problem must be diagnosed and corrected by a qualified gas service technician.

 WARNING

Asphyxiation Hazard. Explosion Hazard. Fire Hazard. Failure of the boiler to fire upon a call 

for heat is usually the result of a potential safety issue (such as a blocked vent) that has 

been detected by the control system. Call a qualified gas service technician to diagnose and 

correct the problem. 

 WARNING

If any of the conditions listed above are found, follow instructions “TO TURN OFF GAS TO 

APPLIANCE” in Figure 1 and contact a qualified gas service technician to correct the problem 

before placing the boiler back in service. Failure to correct these conditions could result in 

property damage, personal injury or loss of life.

 WARNING

Carbon (“soot”) in or near the vent system or boiler is an indication of a potential carbon 

monoxide hazard. If carbon is found, immediately follow instructions “TO TURN OFF GAS TO 

APPLIANCE” in Figure 1 and contact a qualified gas service technician to correct the problem 

before placing the boiler back in service.

II. Maintenance

1. 

On a continuous basis:

Keep the area around the boiler free from combustible materials, gasoline, and other flammable vapors and liquids.

• 

Keep the area around the combustion air inlet terminal and the area around the boiler free from contaminants, includ

-

• 

ing all sources of hydrocarbons such as bleaches, fabric softeners, chemicals, sprays, cleaners, paints, paint removers, 

refrigerants, and cat boxes. Traces of these chemicals can be drawn into the boiler, causing severe corrosion damage to 

the boiler and/or objectionable odors.
Keep the boiler room ventilation openings open and unobstructed.

• 

Do not expose the boiler to large amounts of dust such as that generated by drywall construction or woodworking.

• 

2. 

On a monthly basis:

Inspect outdoor vent and combustion air intake terminals for obstructions, damage due to impact or other deterioration.

• 

Inspect vent and combustion air exterior wall penetrations to be sure they are weather tight.

• 

Inspect all vent and combustion air intake piping for cracks, loose joints, condensate leakage, sags in horizontal runs of 

• 

pipe, corrosion, loose supports or other deterioration.
Inspect vent terminals, exterior of vent system and boiler exterior for carbon (soot).

• 

Inspect water, gas and condensate drain lines for leaks.

• 

Lift off front door and inspect visible controls, wiring and sheet metal components for deterioration. 

• 

Содержание X210

Страница 1: ...stallation and service must be performed by a qualified installer service agency or the gas supplier AVERTISSEMENT Assurez vous de bien suivre les instruc tions données dans cette notice pour réduire au minimum le risque d incendie ou d explosion ou pour éviter tout dommage matériel toute blessure ou la mort Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflammables dans ...

Страница 2: ...trol system and any gas control which has been under water Should overheating occur or the gas supply fail to shut off do not turn off or disconnect the electrical supply to the pump Instead shut off the gas supply at a location external to the appliance En cas de surchauffe ou si l admission de gaz ne peut être coupée ne pas couper ni débrancher l alimentation électrique de la pompe Fermer plutôt...

Страница 3: ...or loss of life WARNING Carbon soot in or near the vent system or boiler is an indication of a potential carbon monoxide hazard If carbon is found immediately follow instructions TO TURN OFF GAS TO APPLIANCE in Figure 1 and contact a qualified gas service technician to correct the problem before placing the boiler back in service II Maintenance 1 On a continuous basis Keep the area around the boil...

Страница 4: ... by frequent additions of water or by the addition of boiler water additives which are not designed for use with stainless steel boilers If it is necessary to add water to the boiler have a service technician check the system for leaks Do not add any chemicals to the boiler not listed in Section XI of the Phantom Installation and Operating Manual Warranty is void if the service and maintenance pro...

Страница 5: ...4 5 Figure 2 Lighting Instructions OSLQH 6HULHV LJKWLQJ DQG 2SHUDWLQJ QVWUXFWLRQV Figure 1 Lighting and Operating Instructions ...

Страница 6: ...s to assure adequate ventilation Wash all exposed body areas gently with soap and water after contact Wash work clothes separately from other laundry and rinse washing machine after use to avoid contaminating other clothes Discard used RCF components by sealing in an airtight plastic bag RCF and crystalline silica are not classified as hazardous wastes in the United States and Canada First Aid Pro...

Отзывы: