36.3 Table of malfunctions
Malfunction
Possible cause
Solution
Performed by
Machine does
not start
Power cable is defective
Repair the power cable
Service technician
Main switch not activated
Turn on the main switch
Operator
Circuit breaker triggered
Reset the FI circuit breaker
Service technician
Safety shut-down triggered
Close the protective grille,
check safety switch
Operator
Machine does
not respond
Safety shut-down responds
Close grille, check switch
Operator
Material hopper too full
Disconnect and clean slide
Operator
Mixing unit has jammed
(stones too large)
Eliminate the cause of the jam
and start up again
Operator
Not enough water
Increase the quantity of water
Operator
Motor protection switch triggered
– too full or mixing unit jammed
Open slide and empty,
then start up again
Operator
37 Maintenance
37.1 Safety
Personnel
Unless otherwise stated, the maintenance work detailed
here can be carried out by the machine operator.
Some tasks may only be carried out by specially trained
personnel or only by the manufacturer.
Work on electrical systems must always only be carried out by
qualified electricians.