PFT SCREW MIXER HM 24 Overview – Operation – Spare Parts Lists
Connections
12
2017-08-07
8.3 Connection without control box 230V
Fig. 8: Electrical connection
2. Three-phase current connection (1), 230 V.
8.4 Connection HM 24 with control box
Fig. 9: Connection control box
1. Operation press button ON - OFF.
2. Blind plug / connector KPS1 probe.
3. Master switch is also emergency-stop switch.
4.
Connection
water pressure booster pump.
5.
Connection
geared motor.
6.
Connection
for vibrating unit.
7. Yellow pilot lamp, for wrong direction of rotation.
1
2
3
7
6
5
4