background image

22

© 2021 United States Stove Company

REPAIR PARTS

4

3

1

5

6

7

2

9

8

10

11

Key

Part #

Description

Qty

1

25491 Feed Door

1

2

25492 Handle, Door

1

3

83506 Roll Pin, 3/8 x 1-1/4

1

4

891135 Handle, Spring (Parts Bag)

1

5

88112 Gasket, 1/2” Sq. Rope

5 ft

6

88087 Gasket, Glass (1 x 3/16)

4 ft

7

891131 Glass Ceramic

1

8

25464 Retainer, Top Glass

1

9

25465 Retainer, Bottom Glass

1

10

83202 Machine Screw

4

11

83278 #10 Flat Washer

4

To order parts:
Call 1-800-750-2723 Ext 5051 or
Email to: [email protected]

IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING USSC PARTS PURCHASED 

THROUGH YOUR DEALER OR DIRECTLY FROM USSC. USE OF THIRD PARTY COMPONENTS WILL VOID THE 

WARRANTY.

Содержание 6041i

Страница 1: ...local building or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Saf...

Страница 2: ...ISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER S MANUAL For Customer Service please call 1 800 750 2723 Ext 5050 or Text to 423 301 5624 or Email us at customerservice usstove com Note Register your product online at www usstove com or download the free app today This app is available only on the App Store for iPhone and iPad Search US Stove Save your receipt with your records for any claims ...

Страница 3: ...rand_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructio...

Страница 4: ...crews CONTROL BOARD PCB RE LOCATION Remove the left side front panel from the unit While holding the PCB with one hand remove the two 2 hex head screws holding the board in place It is not necessary to unplug the PCB cable Route the board and cable through the opening and mount it to the Left Facade using two of the 10 x 1 2 phillips head screws provided Then attach the PCB cover to the back of th...

Страница 5: ...ion et fermer l arrivée de combustib bouton On Off pour continuer à faire marcher le poêle FIGURE 20 SAFETY NOTICE IF THIS STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS CONTACTYOURLOCALBUILDINGOFFICIALSTO OBTAIN A PERMIT AND INFORMATION ON ANY ADDITIONAL INSTALLATION RESTRICTIONS OR INSPECTION REQUIREMENTS IN YOUR AREA DO NO...

Страница 6: ... protector must extend a minimum of 6 152mm in front and 6 152mm from each side of the unit A FLOOR PROTECTOR TO FRONT OF UNIT 6 B FLOOR PROTECTOR TO SIDE OF UNIT 6 C LEFT SIDE OF UNIT TO WALL 8 D FLOOR TO MANTEL 53 A HEIGHT 24 B WIDTH 40 C DEPTH 20 A BACK OF UNIT TO WALL 6 B RIGHT SIDE OF UNIT TO WALL 1 C LEFT SIDE OF UNIT TO WALL 6 D TOP OF UNIT TO WALL 1 OUTSIDE AIR SUPPLY OPTIONAL UNLESS INSTA...

Страница 7: ... carports garage attic crawl space under a sundeck or porch narrow walkway or close area or any location that can build up a concentration of fumes such as a stairwell covered breezeway etc Vent surfaces can get hot enough to cause burns if touched by children Noncombustible shielding or guards may be required Do not install a flue damper in the exhaust vent of this unit Termination must exhaust a...

Страница 8: ... ft clearance from any adjacent building G Min 7 ft clearance from any grade when adjacent to public walkways H Min 2 ft clearance above any grass plants or other combustible materials I Min 3 ft clearance from a forced air intake of any appliance J Min 2 ft clearance below eaves or overhang K Min 1 ft clearance horizontally from combustible wall L Must be a minimum of 36 inches above the roof and...

Страница 9: ...tional building codes Installation must include a chimney liner INSTALLATION INTO A FACTORY BUILT METAL FIREPLACE When installing into a zero clearance fireplace The firebox must accept the insert without modification other than removing bolted or screwed together pieces such as smoke shelf deflectors ash lips screen or door tracks and damper assemblies These items must be re installed if the inse...

Страница 10: ...the manual draft slide to control the combustion air The room fan will come on once the unit has reached operating temperature approx 110 F By pressing the Room Fan buttons the display will show RF A which is automatic or RF 1 through RF 9 for manual settings In auto mode the room fan s speed will automatically be adjusted in accordance with the heat range setting By pressing the Room Fan up arrow...

Страница 11: ...performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could result in a house fire Do not over fire or use volatile fuels or combustibles doing so may cause a personal and property damage hazards THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY Factory appro...

Страница 12: ...E During the first few fires your stove will emit an odor as the high temperature paint cures or becomes seasoned to the metal Maintaining smaller fires will minimize this Avoid placing items on the stovetop during this period because the paint could be affected Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater IGNITOR Close...

Страница 13: ... 15 minutes regardless of whether it is cool or pressure is detected The 15 minute cycle can be turned off by pressing the off button during shutdown This will cause the system to exit shutdown and return to the OFF mode as soon as the door is closed and the heater is cool Continue to monitor the heater insert after the shutdown procedure has begun And remember varying ambient conditions may resul...

Страница 14: ...brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repaired To clean the chimney disconnect the vent from the stove FLY ASH This accumulates in the horizontal portion of an exhaust run Though non combustible it may ...

Страница 15: ...earing gloves carefully remove any loose pieces of glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and rope gasket using high temperature silicone to adhere the gasket to the door 6 Never use substitute materials for the glass DO NOT abuse the door glass by striking slamming or similar trauma Do not...

Страница 16: ...ls below approx 90 degrees At such time the heater will default to the Automatic Shut Down Igniter Starts immediately Will continue operation for a preset time then shut off SHUTDOWN SEQUENCE OF EVENTS Once the Heater has reached the normal operating temperature and switched to the OFF position the unit will initiate a slow down reducing the fuel rate until the heater s LOW LIMIT SAFETY sensor tel...

Страница 17: ...ctrical open in low temperature switch or wiring Fire was not well established before the PCB s programmed time limit expired Err3 The heater was unable to reach the Room Fan On temperature within the startup time Poor flame or fuel quality caused fire to burn too slowly or go out Auger output failure or jam Hopper empty on startup Err4 The power failed while the heater was hot and when power was ...

Страница 18: ... Display This indicates that the heater is in the normal run mode and is ramping from the current heat range setting to the target heat range setting Once the ramp is complete the dash will stop flashing For ramping from heat range 1 to 5 the default time is 12 minutes with a 90 second ramp time Flashing Heat Range Value In Heat Range Display For example if the display is showing Hr 3 and the 3 is...

Страница 19: ... position PROBLEM Cause Auto Start Igniter fails to ignite the fuel in the burnpot Heater does not start a fire when the ON button is pressed Check the pellets quality If moist or damp replace with dryer fuel Check that the auto start igniter port is not blocked with ash or soot The igniter is located behind the burnpot The auto start igniter should glow on start up If you can not visible see the ...

Страница 20: ...BLUE ORANGE YELLOW LOW LIMIT HIGH LIMIT AGITATOR MOTOR POWER SUPPLY MOLEX PLUG TO CIRCUIT BOARD IGNITER BLACK MICROSWITCH PRESSURE SWITCH HOSE To Firebox BLACK ROOM FAN DRAFT FAN WHITE WHITE WHITE WHITE WHITE WIRING SCHEMATIC CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown ...

Страница 21: ...0 F Snap Disc Low Limit 1 9 80473 Exhaust Blower 1 10 88100 Exhaust Blower Gasket 1 11 80390 170 F Snap Disc High Limit 1 12 80575 PCB Circuit Board 1 13 80491 Micro Switch 1 14 891660 Burnpot 1 15 25524 Ash Cleanout Inner 2 1 2 3 4 5 6 7 8 9 11 12 15 14 13 10 To order parts Call 1 800 750 2723 Ext 5051 or Email to parts usstove com INORDERTOMAINTAINWARRANTY COMPONENTSMUSTBEREPLACEDUSINGUSSCPARTSP...

Страница 22: ...Sq Rope 5 ft 6 88087 Gasket Glass 1 x 3 16 4 ft 7 891131 Glass Ceramic 1 8 25464 Retainer Top Glass 1 9 25465 Retainer Bottom Glass 1 10 83202 Machine Screw 4 11 83278 10 Flat Washer 4 To order parts Call 1 800 750 2723 Ext 5051 or Email to parts usstove com INORDERTOMAINTAINWARRANTY COMPONENTSMUSTBEREPLACEDUSINGUSSCPARTSPURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM USSC USE OF THIRD PARTY COMPON...

Страница 23: ..._______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ______________________________________ Stove Inspected Chimney Swept Items Replaced _____________________________________ Service 02 Date _______________________ Engineer Name _____________________________________ License ...

Страница 24: ...24 2021 United States Stove Company NOTES ...