INSTALLATION
US Stove highly recommends your stove be installed by a
qualified NFI (US) or WETT (Canada) technician. To find
the nearest qualified installer, go to:
https://nficertified.org
,
https://www.wettinc.ca/
INSTALLATION CONFIGURATIONS
This insert may be installed as follows:
1. In a pre-fab firebox (Factory Built)
2. In an existing masonry fireplace
3. As a build-in
FLOOR PROTECTION
This heater may be installed on a combustible floor, with
proper floor protection, or on a masonry hearth. The
hearth or noncombustible floor protector must extend a
minimum of 6” (152mm) in front and 6” (152mm) from
each side of the unit.
A FLOOR PROTECTOR TO FRONT OF UNIT 6”
B FLOOR PROTECTOR TO SIDE OF UNIT
6”
C LEFT SIDE OF UNIT TO WALL
8”
D FLOOR TO MANTEL
53”
A HEIGHT 24”
B WIDTH
40”
C DEPTH
20”
A BACK OF UNIT TO WALL
6”
B RIGHT SIDE OF UNIT TO WALL 1”
C LEFT SIDE OF UNIT TO WALL
6”
D TOP OF UNIT TO WALL
1”
OUTSIDE AIR SUPPLY
(OPTIONAL, UNLESS
INSTALLING IN A MOBILE HOME)
Depending on your location and home construction,
outside air may be necessary for optimal performance.
Your stove is approved to be installed with an outside air
intake (69FAK) which is necessary for a mobile home.
You can purchase the 69FAK through your heater dealer.
Installation instructions are supplied with the air intake
kit.