Section 17 |
Recommended Storage
Requirements - Hydraulic
www.pflow.com
P 414 352 9000
F 414 352 9002
6720 N. Teutonia Ave.
Milwaukee, WI 53209
5. The motor pump ships with a full
reservoir tank. Make sure the reservoir
tank remains full to prevent the reservoir
from rusting.
6. Hydraulic cylinders must be stored
horizontally. The environment must
remain constant. All cylinder ends
and ports are to remain capped.
Rotate the cylinders 180 degrees every
two (2) months.
7. Plug the
electrical component
inlets to
prevent moisture and other contaminants
from entering them. Store in a dry,
temperature controlled location to prevent
corrosion. Place silica gel desiccant inside
the control enclosure. Inspect the inside
of the control enclosure for any moisture
build up. See Figure 17-5.
8. Make sure the
parts crate
remains sealed
and dry.
For units stored longer than six months,
it is recommended that you contact the
PFlow Industries, Inc. Customer Support
Department for additional information that
may be available prior to starting up your
unit.
The VRC installation manual, electrical, and
owner’s manuals are located in the parts
container (crate). Do not open the parts
container (crate). If the manuals are required,
contact the PFlow Industries, Inc. Customer
Support Department for an electronic copy
(.pdf).
Long Term Storage
(continued)
Storage for Longer
than Six Months
Equipment Manuals
Place Inside Control Enclosure
Figure 17-5