background image

ENGLISH

ENGLISH

MAINTENANCE & CARE

TROUBLE SHOOTING TIPS

CAUTION:  Maintenance

DISASSEMBLY

1.  Replacement parts may be available at the store where you purchased 

your faucet.

2.  When  replacement  parts  are  not  available,  please  write  or  call  Price 

Pfister Consumer Service.

3. 

Always turn off water and relieve pressure before working on your 

faucet.

NOTE:  Trim Care

Cleaning Instructions:

For all Handles and decorative finishes, use only a soft damp 

cloth to clean and shine.  Use of polish, detergents, abrasive 

cleaners, organic solvents or acid may cause damage.  

Use of 

other than a soft damp cloth will nullify our warranty!

Special Trim:

 Trim products which contain Porcelain or other 

similar  substance  are  not  acceptable  for  public  areas  or 

Commercial use.  Installation of Said Trim is at Users Risk!

Water starts out hot and becomes cooler as handle is ro-

tated counter

clockwise.

This is a potentially hazardous situation and should be corrected 

before using the unit. Check the hot and cold inlet positions (hot- 

left cold-right). If you have a back to back installation, (where 

hot and cold inlets are reversed) refer to Valve Body instruction 

sheets for back to back installation.

Water flows from the shower head while filling the tub.

Check the position of the Valve Body (

J

). The letters “SHWR” 

should be cast into the top and “TUB” on the bottom.

Water doesn’t get hot enough.

Remove Handle (

A

), Sleeve (

B

) and Flange (

C

) and then refer to 

Valve Body instruction sheets for adjusting temperature range.

Water flows from the tub spout while using the shower.

The seal inside of the diverter mechanism may have become 

dislodged. The Spout (

H

) may need replacement.

Temperature or flow does not remain consistent.

The Cartridge Assembly (

D

) may need cleaning. Shut off wa-

ter  supply.    Remove  Handle Assembly  (

A

),  unscrew  Retainer 

Sleeve (

B

) and remove Flange (

C

).  Remove Cartridge assem-

bly (

D

) and inspect Cartridge (

E

) and inlets for debris or sedi-

ment and flush with water. Reassemble whole unit and test.  If 

problem persists you may need to replace the Cartridge (

E

).

Sleeve (B) is too short.

Extension kit 910-563 is available at a nominal charge for valves 

which have been roughed-in too far back in the wall. The kit con-

tains a one inch stem extension, and longer screw and a sleeve 

which is one inch longer than the 972-300.

Dripping from either the tub spout or hand shower.

Clean the Cartridge Assembly (

D

). Check to ensure the two Oval 

O-Rings (

F

) on the back of the Cartridge (

E

) are in place. Reas-

semble cartridge, stem and bonnet assembly and handle. Turn 

on the water and test. If the unit still leaks, replace the Cartridge 

(

E

).

Make sure that both hot and cold water inlets are turned on.

Water flow is very low.

Check the Cartridge Assembly (

D

), for debris. Sediment where 

the  water  enters  the  Shower  Head  (

G

)  can  also  cause  this 

symptom.

1–800–PFAUCET (1–800–732–8238)

For Toll-Free Pfaucet information call 

1–800–PFAUCET (1–800–732–8238) 

or visit www.pfisterfaucets.com

•   Installation Support

•   Care and Warranty Information

5

A

B

C

D

E

G

H

F

J

Содержание Pasadena 8P8-WS1-PHH

Страница 1: ...arant a el comprador original puede 1 llamar al 1 800 Pfaucet 1 800 732 8238 para hablar con un representante de servicio al cliente que lo pueda ayudar o 2 escribir al departamento de servicio al con...

Страница 2: ...move the old unit and clean the mounting surface thoroughly 3 TOOLS RECOMMENDED PTFE plumber s tape or thread sealant Philips head screwdriver Adjustable wrench Pipe wrench Flashlight Cloth Your inst...

Страница 3: ...ghten until Spout is properly positioned and flush to the finished wall 9 SHOWER ARM INSTALLATION Insert the end of Shower Arm 9A through the Shower Flange 9B Apply PTFE plumber s tape to back end of...

Страница 4: ...eign matter clears the line 13 TUB SPOUT FUNCTION When the valve is turned on water normally flows through the Tub Spout 13A To activate the shower turn valve on and pull the Knob 13B up Hold on until...

Страница 5: ...nge C and then refer to Valve Body instruction sheets for adjusting temperature range Water flows from the tub spout while using the shower The seal inside of the diverter mechanism may have become di...

Страница 6: ...r en cruz Llave ajustable Llave para tuber as Linterna de mano Pa o Para instalar el conducto se necesita un acoplador para tuber as as como otras herramientas adicionales 4 REVISI N DEL CONTENIDO DE...

Страница 7: ...loque cinta PTFE en ambos extremos del acoplador de la tuber a 10A no se incluye Enrosque el acoplador de la tuber a 10A en el codo dentro de la pared y apri telo con una llave para tuber as El acopla...

Страница 8: ...TIVACI N DE LA UNIDAD Active el suministro de agua fr a as como el de agua caliente verifique que no hay fugas 12 FUNCIONAMIENTO DE LA V LVULA Al girar un poco la palanca de la v lvula 12A en el senti...

Страница 9: ...ucto H La temperatura o el flujo no permanece constante Podr a ser necesario limpiar el conjunto del cartucho D Desactive el suministro de agua Quite el conjunto de la manija A desenrosque el manguito...

Страница 10: ...ce de montage 3 OUTILLAGE RECOMMAND Ruban PTFE de plombier ou mastic d tanch it de filetage Tournevis cruciforme Cl molette Cl serre tube Lampe de poche Chiffon L installation exige un manchon filet p...

Страница 11: ...ontre le mur 10 POSE DU BEC Coller du ruban PTFE de plombier sur les deux extr mit s du manchon filet 10A non fourni Visser le manchon filet 10A dans le coude qui se trouve l int rieur du mur et le se...

Страница 12: ...age final ouvrir le mitigeur et laisser l eau s couler du bec de baignoire 15A pendant quelques minutes Tirer sur le bouton 15B du bec pour permettre l eau de circuler dans le tuyau de douche 15C pend...

Страница 13: ...e de 25 mm 1 po d une vis plus longue et d un manchon d une longueur sup rieure de 25 mm 1 po celle du 972 300 gouttement du bec de baignoire ou de la douchette Nettoyer l ensemble cartouche D Le v ri...

Страница 14: ...La Fini A Polished Chrome Cromo Pulido Chrome Poli J PVD Brushed Nickel PVD N quel Cepillado PVD Nickel Bross 972 300 971 023 950 620 973 127 951 089 973 076 971 024 973 030 Contains ASME A112 18 3 Ce...

Отзывы: