2.1 Safety precautions

• Observe all safety and accident prevention regulations.

• Regularly check the proper observance off all safety measures.

• Do not loosen any plug connection during operations.

• Keep leads and cables well away from hot surfaces (> 70 °C).

• The unit has been accredited with protection class IP 65. When installing into 

ambient conditions, which afford other protection classes, the necessary mea-
sures must be taken.

• Always ensure a safe connection to the protective earthing conductor (PE, pro-

tection class I).

• Before carrying out any work disconnect the unit and all associated installations 

safely from the mains.

2.2 Proper use

• The relay box may only be used to control vacuum backing pumps on Pfeiffer 

Vacuum turbopumps with related electronic drive units.

• The relay box may only be used up to the specified maximum contact load.

• Permissible electronic drive units for the connection of the relay boxes:

– integrated electronic drive unit TC 110 with connection cable
– integrated electronic drive unit TC 110 with TCS 12
– integrated electronic drive unit TC 400
– integrated electronic drive unit TC 400 with Y-Connector
– integrated electronic drive unit TC 1200
– integrated electronic drive unit TC 1200 with Y-Connector
– integrated electronic drive unit TM 3000 with adapter cable
– external electronic drive unit TCP 350 with adapter cable

2.3 Improper use

Improper use will cause all claims for liability and warranties to be forfeited. Im-
proper use is deemed to be all use for purposes deviating from those mentioned 
above, especially:

• The connection of a mains power voltage not corresponding to the rating plate

• Operation with contact loads higher than the information on the rating plate

NOTE

Duty to inform

Each person involved in the installation or operation of the unit must read and observe 
the safety-related parts of these operating instuctions.

The operator is obligated to make operating personnel aware of dangers originating 
from the unit or the entire system.

NOTE

CE conformity

The manufacturer's declaration becomes invalid if the operator modifies the original 
product or installs additional components!

Following installation into a plant and before commissioning, the operator must 
check the entire system for compliance with the valid EU directives and reassess it 
accordingly.

Содержание PM 061 372-T

Страница 1: ...Betriebsanleitung Operating Instructions PT 0294 BEN B 1005 Backing pump relay box PM 061 372 T PM 061 373 T PM 061 374 T PM 061 375 T...

Страница 2: ...2 3 Improper use 4 3 Product description 5 3 1 Relay box 1 phase PM 061 372 T PM 061 374 T 5 3 2 Relay box 1 phase PM 061 373 T PM 061 375 T 5 4 Installation 6 4 1 Electrical connection 6 4 2 Connect...

Страница 3: ...on international certification standards as specified by UL CSA ANSI Z 535 SEMI S1 ISO 3864 and DIN 4844 In this document the following hazard levels and information are considered Pictograph defini t...

Страница 4: ...tronic drive unit TC 400 integrated electronic drive unit TC 400 with Y Connector integrated electronic drive unit TC 1200 integrated electronic drive unit TC 1200 with Y Connector integrated electron...

Страница 5: ...vacuum pumps The maximum relay contact load is 5 A 3 2 Relay box 1 phase PM 061 373 T PM 061 375 T The relay box PM 061 373 T PM 061 375 T with mechanical relay is provided for the operation of large...

Страница 6: ...by trained and authorised electricians Ensure the system is adequately earthed Establish an adequate fuse protection on customer side depending on the model Fig 3 Backing pump relay box 5 A internal v...

Страница 7: ...1 PE F2 4 A F1 4 A 3 x 1 5 mm2 Mains input 1 2 4 3 Potential separation 6 mm U1 X3 1 3 2 X1 N L 3 x 1 5 mm2 PE N L Backing pump n c M8 M12 n c PM 061 372 T PM 061 374 T M8 M12 insulate M PE N L1 PE 3...

Страница 8: ...ng pump Make the settings and control via the interfaces of the electronic drive unit TC 400 Connect the control lead of the relay box directly to a vacant accessory port of the electronic drive unit...

Страница 9: ...P 350 Connect the control lead of the relay box to the remote connection of the elec tronic drive unit using an adapter cable Establish the mains supply for the relay box according to the accessory op...

Страница 10: ...th accessory ports and bridges other lengths on re quest PM 061 552 T TCS 12 adapter for TC 110 with interface RS 485 and 4 accessory ports PM 061 638 U Y Connector M12 for accessories P 4723 012 Adap...

Страница 11: ...1 Technical data 6 1 Dimensions Fig 7 PM 061 372 T PM 061 374 T Fig 8 PM 061 373 T PM 061 375 T 73 49 24 57 19 5 65 94 PG 9 PG 7 PG 11 120 85 A B A B 52 25 40 80 35 40 80 18 5 12 5 18 5 PG 9 PG 7 PG 1...

Страница 12: ...ective 2004 108 EEC and EU Low Voltage Directive 2006 95 EEC PM 061 372 T PM 061 373 T PM 061 374 T PM 061 375 T Guidelines harmonised standards and national standards and specifications which have be...

Страница 13: ...0 64 41 8 02 2 02 info pfeiffer vacuum de www pfeiffer vacuum net Vacuum is nothing but everything to us Turbopumps Rotary vane pumps Roots pumps Dry compressing pumps Leak detectors Valves Component...

Отзывы: