Type designation
MVP 070-3
MVP 070-3
MVP 070-3
MVP 070-3
MVP 070-3
Part number
PK T01 310
PK T01 311
PK T01 313
PK T01 314
PK T01 315
Operating altitude,
max.
2000 m
2000 m
2000 m
2000 m
2000 m
Protection degree
IP40
IP40
IP40
IP40
IP40
Ambient temperature
10 – 40 °C
10 – 40 °C
10 – 40 °C
10 – 40 °C
10 – 40 °C
Temperature: Storage
-10 – 60 °C
-10 – 60 °C
-10 – 60 °C
-10 – 60 °C
-10 – 60 °C
Degree of pollution
–
–
–
–
–
Weight
16.4 kg
16.4 kg
16.4 kg
16.4 kg
16.4 kg
Tbl. 16:
Technical data, MVP 070-3
Type designation
MVP 070-3 C
MVP 070-3 C
Part number
PK T01 360
PK T01 361
Number of pumping stages
4
4
Connection flange (in)
DN 16 ISO-KF
DN 16 ISO-KF
Connection flange (out)
Hose clamp 10 mm
Hose clamp 10 mm
Pumping speed at 50 Hz
3.4 m³/h
3.4 m³/h
Pumping speed at 60 Hz
3.8 m³/h
3.8 m³/h
Gas ballast
Yes
Yes
Final pressure without gas ballast 1.5 hPa
1.5 hPa
Final pressure with gas ballast
3 hPa
3 hPa
Intake pressure max.
1100 hPa
1100 hPa
Exhaust pressure, max.
1100 hPa
1100 hPa
Integral leakage rate
≤ 2 · 10
-3
Pa m³/s
2 · 10
-3
Pa m³/s
Input voltage(s)
100 – 115 / 200 – 230 V AC,
50 Hz // 100 – 115 / 120 / 200
– 230 V AC (±10 %), 60 Hz
100 – 115 / 200 – 230 V AC,
50 Hz // 100 – 115 / 120 / 200
– 230 V AC (±10 %), 60 Hz
Input voltage: tolerance
±10 %
±10 %
Rated current consumption
5.7 A
5.7 A
Rotation speed at 50 Hz
1500 rpm
1500 rpm
Rotation speed at 60 Hz
1800 rpm
1800 rpm
Sound pressure level
50 dB(A)
50 dB(A)
Switch included
Yes
No
Motor type
1-ph motor
1-ph motor
Cooling method
Air
Air
Operating altitude, max.
2000 m
2000 m
Protection degree
IP40
IP40
Ambient temperature
10 – 40 °C
10 – 40 °C
Temperature: Storage
-10 – 60 °C
-10 – 60 °C
Degree of pollution
–
–
Weight
14.3 kg
14.3 kg
Tbl. 17:
Technical data MVP 070-3 C
14.3 Substances in contact with the media
Pump parts
MVP 040-2
MVP 070-3
MVP 070-3 C
Housing cover
Aluminum alloy (AlMg-
Si)
Aluminum alloy (AlMg-
Si)
-
Head cover
Aluminum alloy (AlMg-
Si)
Aluminum alloy (AlMg-
Si)
ETFE, strengthened with
carbon fibers
Technical data and dimensions