40
Technical data and dimensions
13.2 Technical data
Table 1: Typical ultimate pressure according to PNEUROP
Table 2: Typical ultimate pressure according to PNEUROP
Parameter
Duo 255
Flange (in)
DN 100 ISO-F
Flange (out)
DN 100 ISO-F
Pumping speed at 50 Hz
250 m
3
/h
Pumping speed at 60 Hz
300 m
3
/h
Ultimate pressure with gas ballast
4 · 10
-3
hPa
Ultimate pressure without gas ballast
3 · 10
-3
hPa
Exhaust pressure, min.
250 hPa
Exhaust pressure, max.
1500 hPa
Rotation speed at 50 Hz
1000 min
-1
Rotation speed at 60 Hz
1200 min
-1
Leak rate safety valve
1 · 10
-5
Pa m
3
/s
Emission sound pressure level without gas ballast at 50
Hz
75 dB (A)
Ambient temperature
12-40 °C
Protection category
IP 55
Rated power 50 Hz
7.5 kW
Rated power 60 Hz
9.0 kW
Switch
No
Mains cable
No
Shipping and storage temperature
-25-+55 °C
Operating fluid filling
25 l
Weight
360 kg
Cooling method, standard
Air
Parameter
Duo 255 M
Flange (in)
DN 100 ISO-F
Flange (out)
DN 100 ISO-F
Pumping speed at 50 Hz
250 m
3
/h
Pumping speed at 60 Hz
300 m
3
/h
Ultimate pressure with gas ballast
4 · 10
-3
hPa
Ultimate pressure without gas ballast
3 · 10
-3
hPa
Exhaust pressure, min.
250 hPa
Exhaust pressure, max.
1500 hPa
Rotation speed at 50 Hz
1000 min
-1
Rotation speed at 60 Hz
1200 min
-1
Leak rate safety valve
1 · 10
-5
Pa m
3
/s
Emission sound pressure level without gas ballast at 50
Hz
75 dB (A)
Ambient temperature
12-40 °C
Protection category
IP 55
Rated power 50 Hz
7.5 kW
Rated power 60 Hz
9 kW
Switch
No
Mains cable
No
Shipping and storage temperature
-25-+55 °C
Operating fluid filling
25 l
Weight
397 kg
Cooling method, standard
Air