background image

FF

FF

II

II

Vaatimustenmukaisuus vakuutus seuraavien EU-direktiivien mukaisesti:

- konedirektiivi 89/392/ETY
- sähkömagneettinen siedettävyys 89/336/ETY
- pienjännite 73/23/ETY

Vahvistamme, täten, että allamainittu tuote vastaa EU-konedirektiivin 89/392/ETY - liite IIA,  EU-direktiivin sähkömagneettinen siedettävyys 89/336/ETY ja EU-pien-
jännitedirektiivin 73/23/ETY vaatimuksia.
Soveltamamme suuntaviitat, harmonisoidut standardit, kansalliset standardit ja rakennemääräykset on luteltu alempana.

P

P

P

P

T

T

T

T

Declaração de conformidade, de acordo com as seguintes Directivas CE:

- Máquinas, na redacção 89/392/CEE
- Compatibilidade electromagnética, na redacção 89/336/CEE
- Baixa tensão, na redacção 73/23/CEE

Com a presente, declaramos que o produto abaixo indicado está em conformidade com as disposições pertinentes na Directiva CE para máquinas, na redacção
89/392/CEE - Apêndice II A, na Directiva CE sobre compatibilidade electromagnética, na redacção 89/336/CEE, e na Directiva CE sobre baixa tensão, na
redacção 73/23/CEE. Abaixo, dá-se indicação das directivas aplicadas, das normas harmonizadas e das normas e especificações aplicades no respectivo país.

G

G

G

G

R

R

R

R

Produkt/Product/Produit/Prodotto/Producto/Produkt/Produkt/Produto/

UNO 005 A
UNO/DUO 2.5 A
UNO/DUO 2.5 AC

Angewendete Richtlinien, harmonisierte Normen und angewendete, nationale Normen in Sprachen und Spezifikationen:
Guidelines, harmonised standards, national standards in languages and specifications which have been applied:
Les directives appliquées, normes harmonisées et les normes nationales appliquées en langues et spécifications:
Direttive aplicate, norme standardizzate e norme nazionali utilizzate in lingue e specifiche:
Directivas aplicadas, normas armonizadas y normas nacionales aplicadas en idiomas y especificaciones:
Toegepaste richtlijnen, geharmoniseerde normen en toegepaste nationale normen met betrekking tot talen en specificaties:
Anvendte direktiver, harmoniserede standarder og de anvendte nationale standarder med sprog og specifikationer:
Directivas aplicadas, normas harmonizadas e normas aplicadas na linguagem e nas especificações do respectivo país:

EN 292-1

EN 60335-1, -41

EN 292-2

EN 61 010

EN 294
EN 50 081-1
EN 50 082-1

Unterschriften/Signatures/Signature/Firme/Firmas/Handtekeningen/Underskrifter/Assinaturas/

01. 04.1996

Geschäftsführer         (W. Dondorf)
Managing Director
Gérant d’affairs
Gerente
Directeur
Administrerende Direktør
Verkställande Direktör
Gerente

DTP 

Konf.I/9606

Form.-Nr. 10118 / (9606)

Содержание DUO 2.5 A

Страница 1: ...Operating Instructions Rotary Vane Vacuum Pumps UNO 005 A UNO DUO 2 5 A UNO DUO 2 5 AC PK 800 152 BGB F 9911...

Страница 2: ...em Modifications reserved Danger of burns from touching hot parts 1 Safety Precautions Danger of personal injury 1 Safety Precautions 2 1 1 For Your Orientation 2 2 Understanding The Pump 3 2 1 Main F...

Страница 3: ...um connection and the pumping system The valve closes off the vacuum equipment without delay when the pump is at a standstill and vents the pump The Rotary Vane Vacuum Pumps are in two versions availa...

Страница 4: ...uctance value of the accessory there is a reduction in volume flow rate For the intake lines metal or PVC hoses with small flanges are available for laboratory work 3 4 Connecting The Exhaust Side Pre...

Страница 5: ...values The single phase drive motors of the UNO 005 A 2 5 A and the DUO 2 5 A AC are fitted with a built in thermal protection switch A cable with connecting plug is fitted to the motor for mains con...

Страница 6: ...id is possible when the pump is in final vacuum operations If there is a noticeable loss of pump fluid the casing and the radial shaft seals should be checked for leaks see Service Instructions 4 2 Sw...

Страница 7: ...cer 40 is a nozzle inside the pump housing and cannot be altered when dirty it should either be cleaned or replaced see Service Instructions 7 1 7 2 7 4 Gas ballast valve 7 for Corrosive Gas Processes...

Страница 8: ...P3 can be read off from the colour scale in accordance with DIN 51578 on the supplementary sheet PK 800 219 BN B on request The colour scale enables precise colour determination Fill a specimen in a...

Страница 9: ...erials in accordance with the Code of Federal Regulations CFR 49 Part 173 240 Definition and Preparation We will carry out the decontamination and invoice this work to you if you have not attached thi...

Страница 10: ...mbar 5 10 2 5 10 2 5 0 10 3 Total with gas ballast mbar 1 1 6 0 10 3 Max pressure in continuous operation bar 1 5 1 5 1 5 Water vapour compatibility mbar 20 15 15 Water vapour capacity at 50 60 Hz g...

Страница 11: ...s catalogue contains details of a comprehensive accessory programme which can both extend the range of application of the pump and provide protection against wear and tear under extreme operating cond...

Страница 12: ...full part number When ordering spare parts please state additionally the unit type and unit number see rating plate Please use this list as an order form by taking a copy Spare parts UNO 005 A Standar...

Страница 13: ...he repair and or service of vacuum components will only be carried out if a correctly completed declaration has been submitted Non completion will result in delay The manufacturer could refuse to acce...

Страница 14: ...tate in basso le direttive aplicate le norme standardizzate nonch le norme e le specifiche nazionali utilizatte E E E ES S S S Declaraci n de conformidad al tenor de las siguientes Directivas de la UE...

Страница 15: ...G G GR R R R Produkt Product Produit Prodotto Producto Produkt Produkt Produto UNO 005 A UNO DUO 2 5 A UNO DUO 2 5 AC Angewendete Richtlinien harmonisierte Normen und angewendete nationale Normen in...

Страница 16: ...2 259 6243 U S A Pfeiffer Vacuum Inc 24 Trafalgar Square Nashua NH 03063 1988 USA telephone 1 603 578 6500 telefax 1 603 578 6550 Venezuela Secotec S A Apartado 3452 Caracas 1010 A telephone 58 2 573...