Quadro LED-RGB-3G/3D Operating Instructions
07/2020
Page 3 / 8
086200012
en
4.2 Electrical data
Rated voltage range
12 V
– 48 V DC
115 V
– 230 V AC
Operation voltage range
10
– 57 V DC
95
– 253 V AC
Rated frequency
--
50/ 60 Hz
Rated current consumption range
276 mA
– 64 mA
51 mA
– 36 mA
Rated power (max.)
3.3 W
8.3 VA
Operation voltage
12 V
24 V
48 V
115 V
230 V
Current consumption
RMS
(LED color yellow)
[mA]
Flashing light 0.75 Hz
159
73
41
33
25
Flashing light 1 Hz
183
85
47
37
27
Continuous light
76
41
33
31
25
Blinking light 1 Hz
54
30
25
24
21
Flashing light 2 Hz
276
120
64
51
36
Blinking light 2 Hz
51
27
22
25
22
Flashing light 0.1 Hz
60
28
19
20
19
Flashing light 0.5 Hz
131
60
34
28
22
DFM3
(option)
214
96
53
43
32
Max. current con-
sumption
(LED color yellow)
[mA]
Flashing light 1 Hz
583
291
167
396
372
Flashing light 2 Hz
578
290
168
392
368
Blinking light 2 Hz
86
55
52
158
170
5. Conformity to standards/ designations
Conformity to standards:
Directive 2014/34/EU (ATEX)
(Explosion protection)
EN 60079-0
EN 60079-15
EN 60079-31
Designation
II3G Ex nRc IIC T6 Gc (-20°C
Ta
+55°C)
PDG 20.0008 X
II3D Ex tc IIIB T80°C Dc IP66/67 (-20°C
Ta
+55°C)
Special application conditions X
X:
The device is suitable for a low degree of mechanical hazard in accordance with the requirements of EN
60079-0. This means:
➢
The device must be mounted protected against impact.
A protective basket is not absolutely necessary.
in the operating manual to prevent possible hazardous electrostatic discharges
from the housing surface in potentially explosive gas atmospheres:
➢
The device must only be wet-cleaned.
➢
Avoid unintentional and dry rubbing.
An installation height of > 2.50 m or comparable protective measures is therefore suggested.
The device is designed for connection to permanently installed connection cables. The cable glands are suita-
ble for stationary cables and wires.
The device is usually not intended for opening after installation.
If it should nevertheless become necessary to open the device (e.g. to change the operating mode or replace
original spare parts):
➢
➢
Observe chapter
Maintenance, service, repairs!