Adjusting
44
1
.07.12
Parameter values
The following parameters has to be set diffrent to the regulare
P
74
ED instruction manual.
Group
P
arameter
Description
User level
S
e
tting range
S
et value
3
309
Position short trimmer on
B, C
0 - 255
180
310
F
unctions A16
0 = no function
1 = midle guide
2 = short trimmer
B, C
0 - 2
2
312
Selection of midle guide
B, C
ON - OFF
OFF
314
Funkctions A7
0 = no function
1 = edge trimmer
2 = thread-pulling sewing start
B, C
0 - 2
0
315
Funkctions A15
0 = no function
1 = Faclean thread-monitor
2 = Thread-pulling at sewing-start
B, C
0 - 2
0
316
Position to pull thread at seam-start
B, C
0 - 255
235
317
Time to pull the thread at sewing-start
B, C
10 - 1000
100
6
657
Stitch protection / knotting
B, C
ON - OFF
ON
7
702
1 Needle position (down)
B, C
0 - 255
20
703
Thread lever position up
B, C
0 - 255
235
705
End trim signal1
B, C
0 - 255
210
706
Start trim signal
B, C
0 - 255
100
707
Start thread tension release
B, C
0 - 255
190
9
989
Thread-nipper at sewing-start
0 = Thread-nipper off
1 = Thread-nipper without foot-lift
2 = Thread-nipper with foot-lift
B, C
0 - 2
1
Содержание Powerline 2545
Страница 47: ...47 Circuit diagrams Version 27 07 07 91 191 523 95 Part 1 ...
Страница 48: ...48 91 191 523 95 Part 2 Version 27 07 07 Circuit diagrams ...
Страница 51: ...51 Circuit diagrams Version 10 08 10 91 191 519 95 Part 1 ...
Страница 52: ...52 91 191 519 95 Part 2 Version 20 04 12 Circuit diagrams ...
Страница 53: ...53 Circuit diagrams Version 20 04 12 91 191 519 95 Part 3 ...
Страница 54: ...54 91 191 519 95 Part 4 Version 20 04 12 Circuit diagrams ...