Adjustment
11 - 19
61-036
11
.04.15
Stitch length control eccentric
Requirement
When the needle (with maximum stitch length set), coming from TDC, is
3 mm
above the
needle plate, the crank
3
must have reached its front point of reversal.
2
●
Set the maximum stitch length.
●
Turn stitch length control device
1
(screws
2
) according to the
requirement
.
Fig. 11 - 15
1
3
Содержание 571