Adjustment
11 - 55
11
.07.08
Releasing the tension
Requirement
When the magnet is activated, tension discs
3
must be at least
0.5 mm
apart.
Fig. 13 - 51
●
Activate the magnet.
●
Detach the tension bearing plate
1
and adjust pressure plate
2
in accordance with the
requirement.
It is possible to set the time for releasing the tension with the parameter
functions, see
Chapter 11.10 Parameter settings
.
61-043
1
2
3
0.5 mm