Adjustment
14 - 27
14
.25
Needle thread tension release
Requirement
With the presser bar lifter
3
raised the tension discs must be at least
0.5 mm
apart.
●
Adjust the tension release lever
1
(screw
2
) in accordance with the
requirement
.
●
Lower the presser foot onto the needle plate. Now the tension must be fully active.
3
1
2
0.5 mm
Fig. 14 - 25