Adjustment
12 - 41
12
.09
Carry out cold start
●
Switch on the machine.
●
Press
Parameter input
key ( LED on ).
●
Select the required parameter by pressing the
plus/minus key
.
●
Enter the code number ( factory code setting is ”1493” )
●
Confirm input.
●
By pr/- on the
A+B key
select parameter ”604”.
●
Carry out the cold start by pr/- on the
L key
.
●
Switch off the machine.
Following a cold start all programmed values are reset to their condition on
delivery.
600
CODE
0
604
Содержание 3734 - 2/01