Setting up
9 - 6
9
.06.03
Entering the fullness area for the pedal adjustment
With parameter “107“ it is possible to stipulate the maximum stitch length, which can be
called up in infinite variations with the fullness pedal (left pedal).
●
Switch on the machine.
●
Press the
TE/Speed
key twice to call up the parameter input function.
3
2 x
No
VAL
101
II
TE
●
Select parameter “107“ by pressing the corresponding
+/- key.
No
No
VAL
107
4.0
TE
2.5
2.5
VAL
●
By pressing the corresponding
+/- key
, set the maximum stitch length for the fullness
pedal (left pedal).
●
Conclude the parameter input by pressing the
TE/Speed
key. The value enter is stored.
When the fullness pedal is activated, a bar display appears on the screen which shows
the actual amount of fullness in the fullness area entered, dependent on the pedal
setting.
2.5