Mounting and commissioning the machine
8 - 7
8
.02.06
Connecting the safety switch
●
Connect plug
1
of safety switch
2
as
shown in
Fig. 8-09
.
When the sewing head is tilted
back, the safety switch
prevents the machine starting
when the main switch is on.
Fig. 8 - 09
1
2
8
.02.07
Checking the function of the start inhibitor
●
Switch the machine on at the main switch and tilt back the sewing head.
The error message „STOP“ must appear on the control panel.
●
If the message does not appear, check the setting of switch 3
3
3
3
3.
●
After the sewing head has been set upright, the machine is ready for operation again.
2.5 2.5
STOP