Adjustment
13 - 16
13
.05.14
Setting the zero point of the feed regulator
Requirement
When the stitch length is set at "0", at maximum speed (4500 spm) the needle should
always penetrate in the same place.
The permissible values for parameter
834
are
"1", "0"
or
"-1".
If the zero point of the feed regulator cannot be set by selecting one of the
permissible values, the mechanical setting must be checked or corrected, see
Chapter 13.05.03 Zero position of the bottom feed dog.
The zero position of the feed regulator is always recognisable in a range of 3
values. When making the adjustment, select the middle value.
●
Switch off the machine.
Find more information on how to select and alter parameters and about
descriptions (functions) of the individual parameters in
Chapter 13.11 Parameter
settings.
No
VAL
834
0
TE
●
Unthread the machine.
●
Switch on the machine.
●
Place the workpiece under the presser foot.
●
Let the machine sew at maximum speed and
check the
requirement.
(The workpiece should not move).
●
Change the value for parameter
834
within the permissible values in accordance with the
requirement.