
Input
56
11
.04.03
List of parameters
0
10
Bobbin thread monitor current level
C
8 - 16
12
11
Bobbin thread monitor stitch counter
C
0 - 255
32
(Start value)
1
100
Control panel contrast [%]
A
90 - 110
100
101
Control panel key response signal
A
0 - 1
1
0=tone off / 1=tone on
102
Start backtack stitches forwards
C
0 - 9
3
103
Start backtack stitches in reverse
C
0 - 9
3
105
Start backtack speed
B
100 - 1500
900
106
Start backtack speed:
C
OFF - ON
OFF
ON = pedal-controlled
OFF = set with param. "105"
107
Pedal-controlled start backtack speed:
C
OFF - ON
OFF
ON = limited with parameter "105"
OFF = limited with parameter "607"
108
End backtack stitches in reverse
C
0 - 9
3
109
End backtack stitches forwards
C
0 - 9
3
110
End backtack speed
B
100 - 1500 1000
111
No. of stitches from bright light barrier
A
1 - 255
6
to seam end in manual sewing
113
Start with light barrier
B
OFF - ON
ON
ON = only when light barrier is dark
OFF = also when light barrier is bright
114
After light barrier or stitch counting:
C
OFF - ON
OFF
ON = stop
OFF = autom. end backtacks and
seam end
116
Soft starting stitches (soft start)
A
0 - 10
1
117
Speed for soft starting stitches
B
180 - 1200
400
148
Start backtacks
A
OFF - ON
ON
ON = double / OFF = single
149
End backtacks
A
OFF - ON
ON
ON = double / OFF = single
Group
Parameter
Setting
range
Set
value
User
level
Description