Adjustment
87
Fig. 13 - 20
●
Remove cloth plate
1
.
●
Switch on the machine and set parameter "
610
" at "
4
" (button gauge: centre).
●
Insert and align button gauge
2
(part no.
61
-
111
635
-
66
).
●
Press down the button clamp by hand.
●
Adjust button clamp
3
(screws
4
) in accordance with the
requirement
.
●
Check the remaining penetration positions of the needle in the respective hole of the but-
ton gauge
1
with the values "
5
", "
6
", "
7
" and "
8
" of parameter "
610
" in accordance with the
requirement.
●
Connect the machine to the pneumatic power supply and check the setting again.
●
If necessary correct the position of the button clamp
3
(screws
4
).
●
Switch off the machine and disconnect it from the pneumatic power supply.
●
Remove the button gauge and mount the cloth plate.
3
4
4
2
1
Requirement
After parameter "
610"
has been selected (with value
4, 5, 6, 7
and 8), the needle should
penetrate the centre of the respective hole of button gauge
2
.
13
.22
Aligning the button clamp
(only on subclass -1/.. and -7/20)