Adjustment
112
Group
Parameter
Description
Setting
range
Set
value
600
603
Outputs:
Position on the Display
1: Clamp (X13:1)
2: Not assigned (X13:3)
3: Thread clamp (X13:5)
4: Cutting (X13:6)
5: End knotting (X13:7)
6: Thread puller (X13:8)
7: Air jet / thread wiper (X13:9)
8: Not assigned (X13:10)
9: Not assigned (X13:11)
10: Not assigned (X13:12)
11: Not assigned (X13:13)
12: Not assigned (X13:25)
13: Not assigned (X13:24)
14: Shank button holder (X13:16)
15: Programmed outlet 1 (X13:17)
16: Missed stitch lamp (X5:24)
▲
= basic position
0
lowered
-
open
off
▲
off
▲
off
▲
off
▲
-
-
-
-
-
-
off
▲
-
off
▲
I
raised
▲
-
closed
▲
on
on
on
on
-
-
-
-
-
-
on
-
on
604
Last engaging and disengaging positions
for end knotting
605
Needle penetration point in fabric
0 - 127
43
607
Turn sewing motor in sewing direction
608
Carry out cold start
610
Needle penetration points for
adjustment
1:
Centre
2:
Max. penetration point right
3:
Max. penetration point left
4:
Button gauge: centre
5:
Button gauge: front left
6:
Button gauge: back left
7:
Button gauge: back right
8:
Button gauge: front right
Meaning of the
display value
Содержание 3307-1 Series
Страница 124: ...124 Circuit diagram View Version 13 11 06 91 191 511 95 Part 1...
Страница 125: ...125 91 191 511 95 Part 2 Version 13 11 06 Circuit diagram View...
Страница 126: ...126 Circuit diagram View Version 13 11 06 91 191 511 95 Part 3...
Страница 127: ...127 91 191 511 95 Part 4 Version 13 11 06 Circuit diagram View...
Страница 128: ...128 Circuit diagram View Version 13 11 06 91 191 511 95 Part 5...
Страница 129: ...Note...