![PF monomatic Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/pf/monomatic/monomatic_user-manual_1534146004.webp)
Rev.: 2004-001-GB
4
1 Introduction
Dear customer,
we thank you for the confidence in our product and wish you a contented work with it.
The present instructions manual includes, beside the description of the use of the devices, important
notes for your safety and the scope of application. Therefore, you should read carefully the present
instructions manual before the first use of the device. In case of failure or interruption of the workflow
read the appropriate chapter of this manual. Self-evidently we are ready to assist you at any time:
PF-Schweißtechnologie GmbH
Karl-Bröger-Str. 10
DE-36304 Alsfeld
Tel.:
+49-6631-9652-0
Fax:
+49-6631-9652-52
All notes and technical specification in this instructions manual were prepared with all necessary care.
The manufacturer keeps the right to make technical changes at the device, which are not directly
included into the present instructions manual.
1.1 Maintenance periods
Please note, that the bought product is a technically demanding machine for field application. In
accordance to the applicable standards like DVS 2208-1, BGV A2, ISO 12176-2 and most national and
international standards, these machines have to be subjected to a periodical maintenance. The
maintenance period is 12 month. When the machine is used quite often the maintenance should be
carried out more often.
During the maintenance the machine will be upgraded to the current technical state. Additionally you get
a 3-month function guarantee for the maintained device.
The maintenance and the related checks are important for you safety and the continuous working
reliability of the control unit. Therefore the maintenance and all necessary repairs, have to be carried out
by the manufacturer or a authorised service point.
2 Scope of application and technical data
2.1 Scope of application
The electro fusion control units of type
Monomatic
are exclusively for the electro fusion of thermoplastic
pipes (e.g. made of PE-HD, PE80. PE100 or PP) by use of electro fusion fittings with an welding voltage
lower than 48V . The control units are conform to the standard DVS 2208-1 as well as the ISO 12176-2,
which refer to the standards applicable for the electro fusion fittings to be used.
It is not allowed to use the electro fusion controllers, to which the present instruction manual refers to, for
an application not covered by the above stated terms. The manufacturer is not liable for the use of the
machine out of the scope of application.
2.2 Input of welding parameters
The electro fusion controllers of type
Monomatic
provides the following means for entering the welding
parameters:
FUSAMATIC-System:
By reading out the reference resistance in the connector pins of the FUSAMATIC-Fitting the control unit
automatically takes over the welding data of the fitting.