Advanced Features

Anti-Linger Prevention

The Anti-Linger Prevention feature keeps your pet from staying in the warning 
zone for long periods of time and draining the receiver collar’s rechargeable 
battery. Your pet will hear a 2-second warning tone when he reaches the 
warning zone. If your pet does not return to the pet area after 2 seconds, he 
will receive a continuous static correction until he returns to the pet area or until 
the Over Correction Protection feature is enabled.

Run Through Prevention

This system includes a unique Run Through Prevention feature so that your 
pet cannot “run through” the pet area without receiving an increased level 
of static correction. 

YardMax

® 

Mode

 

When your pet crosses over the wire and passes the warning zone, static 
correction is activated at a variable distance dependent on the height 
of your pet and the height of the receiver activation distance setting. 
The ideal warning zone distance is where the receiver collar activates 
between 1 to 1

1

2  

ft. above your pet’s neck height.

If you have a very timid pet, you may increase the warning zone distance 
to allow more distance before the higher level, run through prevention 
static correction is generated. You can accomplish this by increasing the 
height of the receiver collar activation.

Traditional Mode

 

The receiver collar automatically increases the static correction when your 
pet continues more than 20% of the way through the boundary width. 
For example, if the signal is detected 10 ft. from the wire and your pet 
enters the static correction zone, this feature is activated when he is 
approximately 8 ft. from the boundary wire. Your pet will then receive a 
static correction that is at an increased level corresponding to the static 
correction level setting on the receiver collar.

Over Correction Protection

Over Correction Protection is designed to protect your pet from prolonged 
static correction if he “freezes” in the static correction zone or runs beyond 
the boundary.

YardMax

® 

Mode (A)

 

In the unlikely event that your pet “freezes” or continues beyond the 
boundary, the static correction duration continues for 15 seconds. The 
receiver collar locks out further static correction and the green light will 
remain on for 10 seconds. The receiver collar remains locked out until your 
pet re-enters the pet area.

Traditional Mode (B)

 

In the unlikely event that your pet “freezes” in the static correction zone, 
this feature limits the static correction duration to 15 seconds. While the 
receiver collar locks out further static correction, the green light will remain 
on for 10 seconds. The receiver collar remains locked out until your pet 
leaves the static correction zone.

Содержание PIG00-11115

Страница 1: ...Please read this entire guide before beginning PIG00 11115 YardMax Rechargeable In Ground Fence Operating Guide 1 A B 10 2 5 6 7 8 9 4 3...

Страница 2: ...with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury CAUTION used without the safety alert symbol indicates a hazardous situation...

Страница 3: ...an adjustment is made to the pet area to prevent unintended corrections to your pet Do not change the transmitter setting from Traditional mode B to YardMax mode A without verifying that the receiver...

Страница 4: ...9 Test the Receiver Collar 17 Step 10 Bury the Boundary Wire 19 Step 11 Place the Boundary Flags 20 Step 12 Fit the Receiver Collar 21 Training Guide 22 Day 1 Tone only Training for Boundary Awareness...

Страница 5: ...a tion at the boundary use the labels to identify the Boundary Wire conne ctions to the Transmitter and the Boundary Wire conne ctions to the Surge Protector This will be conve nient to have should an...

Страница 6: ...t and then touch a door handle Of course different pets respond to different levels of correction We have built in 5 levels of correction plus a tone only setting to accommodate any pet The only pets...

Страница 7: ...ng Zone Static Correction Zone Infinite Containment Area 30 More Yard Than Traditional Mode Pet Area Boundary Wire Non Containment Area Exclusion Area Static Correction Zone Finite Containment Area Bo...

Страница 8: ...g can have a negative effect on the battery We recommend that the receiver collar be used until the indicator light blinks red Step 3 Install the Surge Protector and Transmitter Lightning strikes that...

Страница 9: ...duplex outlet with center screw Do not install the surge protector if there is not at least 30 ft 10 m or more of wire between the electrical outlet and electrical service panel If possible DO NOT us...

Страница 10: ...ingle boundary wire that is placed around the entire property 4C or by doubling the boundary wire along the same path 4D Single Loop Boundary 4C To create a containment area for the entire property Us...

Страница 11: ...r 2 run the wire from the fence transmitter to point A then to point B and so on B to C to D to E all the way around the entire property until back to point A again The wires from point A will then ne...

Страница 12: ...he fence transmitter run the wire to point A then to point B Make a U turn and follow your path to C then to D then to E Next make another U turn and follow the same path all the way back to point A k...

Страница 13: ...connect this twisted portion back to the main boundary wire Splicing Guide Although not required it is recommended that you cut and splice the wire between each twisted section Your YardMax system com...

Страница 14: ...you can always check out our troubleshooting section watch one of our instructional videos or give us a call Verify that the boundary loop and transmitter wires are connected to the proper surge prot...

Страница 15: ...very 4 seconds After you adjust the collar on your pet and the contact points are touching his or her skin or if you inadvertently touch both of the contact points with your fingers the receiver colla...

Страница 16: ...approach a straight section of your boundary wire that is at least 50 ft long 7 As you cross the wire 8C you will hear the warning tone and see the test light flash as you walk through the correction...

Страница 17: ...is accomplished 5 Starting inside the pet area slowly walk over to the boundary wire As you cross the wire you will hear the warning tone and see the test light flash as you continue to walk through...

Страница 18: ...10 ft before the boundary wire 7 Repeat this test at different places along the boundary wire to verify that it is working everywhere Note To ensure that the signal is not coupled to any wires or oth...

Страница 19: ...n be attached to a chain link fence split rail fence or a wooden privacy fence The boundary wire can be attached as high as needed However make sure the boundary width is set at a high enough range fo...

Страница 20: ...flags are visual reminders for your pet of where the warning zone is located 1 Place the test light contacts on the contact points Hold the receiver collar at the height of your pet s neck 2 Walk towa...

Страница 21: ...il the skin has fully healed Important The proper fit and placement of your receiver collar is important for effective training The contact points must have direct contact with your pet s skin on the...

Страница 22: ...pending on your pet and your consistency the training could take more or less time Always have small pieces of your pet s favorite treats readily at hand Promptly reward your pet for good behavior If...

Страница 23: ...ntly help him or her back into the pet area 13C Immediately praise and offer your pet a treat as he or she enters the pet area even if you have helped with the leash Note Pulling on the leash is not a...

Страница 24: ...llar does not put pressure on the contact points Have small pieces of your pet s favorite treats available Have your pet s favorite play toy available Stage some distractions to tempt your pet to ente...

Страница 25: ...ar intervals Note After you are satisfied that your pet s training is complete remove every other boundary flag every 4 days until all flags are removed Save your boundary flags for future use Taking...

Страница 26: ...s by increasing the height of the receiver collar activation Traditional Mode The receiver collar automatically increases the static correction when your pet continues more than 20 of the way through...

Страница 27: ...indicator light are not both lit on the fence transmitter or the alarm is on for any of the above tests there is a problem with the transmitter Contact the Customer Care Center b If both the power an...

Страница 28: ...a wire break locator RFA 450 15B Option 2 Follow the procedure below 1 Unplug the fence transmitter 2 Connect both ends of your twisted boundary wire to one loop terminal on the surge protector 3 Mea...

Страница 29: ...yTest startup feature Continuous red green or red green together 5 seconds No tone Battery charge status Flashing red from 1 to 6 times No tone Receiver collar is reporting the static correction level...

Страница 30: ...B only adjust the boundary width dial clockwise to increase the distance from the boundary wire that the receiver collar activates The recommended distance is 10 ft from the boundary wire If using a d...

Страница 31: ...receiver activation height is not greater than 1 ft above the pet s neck height Step 9 on page 17 when crossing the boundary wire There could be an inconsistent signal due to close proximity to telep...

Страница 32: ...on guide may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a practical installation If this equipment causes harmful interference...

Страница 33: ...t Radio Systems does not provide refunds replacements or upgrades for change of mind or for any other reason outside of these Warranty terms Claims Procedure Any claim made under this Warranty should...

Страница 34: ...1 800 732 2677 34 Layout Grids...

Страница 35: ...www petsafe net 35...

Страница 36: ...10427 PetSafe Way Knoxville TN 37932 1 800 732 2677 www petsafe net For a list of patents protecting this product please visit http www petsafe net support policies and terms patents 400 002 3 2016 R...

Отзывы: