background image

12 1-800-732-2677

1.  Turn the power OFF to the outlet that the Surge Protector 

and Fence Transmitter will be plugged into.

2.  We recommend that, if possible, use the outlet center 

screw that holds the cover plate in place to secure the 

Surge Protector to the outlet. To do this, tape the top of 

the cover plate to the wall, then remove the cover plate 

center screw. Plug the Surge Protector into the lower outlet 

and then secure the cover plate using the longer screw 

included with the protector. The screw is for mechanical 

attachment only and does not ground the protector. 

Remove the tape and turn ON the power to the outlet.

3.  Run the Boundary Wire through a window, under a door, 

through a crawl space vent, or any other appropriate 

available access. You can also drill a hole through your wall. 

4.  Strip 

3

8

 inch of insulation from the ends of the Boundary Wire. Insert the stripped 

ends into the 2 left red connector holes on the bottom of the Surge Protector labeled 

“Loop” (

4B

). There should be 1 wire in each connector hole. Press the plastic tab, 

insert the wires and release the tab. Make sure the wires do not touch each other at 

the terminals.

Verify that the boundary loop and transmitter wires connect to the 

proper Surge Protector terminals. Reversed connections will result in an 

increased risk of surge related damage.

5.  Determine the length of wire needed to pass from the Surge Protector to the Fence 

Transmitter. Measure and cut 2 lengths of wire, then strip 

3

8

 inch of insulation at both 

ends. Twist the 2 lengths together, with at least 10-12 twists per foot, so the wires will 

not send out a signal.

6.  Insert the ends of the the twisted transmitter wires into the right 2 black connectors at the bottom  

of the Surge Protector labeled “Transmitter”. 

7.  Press the red plastic tabs on the Fence Transmitter and insert the opposite ends of the twisted wire  

into the Boundary Wire Terminals.

8.  Turn the Boundary Width Control knob to 10. This will set the Boundary Width at the maximum width.
9.  Plug in the transmitter power adapter to the outlet on the front of the Surge Protector.
10. The Power Light and Loop Indicator Lights should come on. If this does not happen, see the  

“Troubleshooting” section.

For added protection, when unused for long periods of time or prior to thunderstorms, unplug   

from the wall outlet and disconnect the loop boundary wires. This will prevent damage to the 

transmitter due to surges.

LOOP      TRAN

SMITTER

Push Tab

Down

Insert bare end 

of wire into 

opened slot 

and release tab 

to lock.

4B

Fence Transmitter

Power

Adapter

Red Loop Tabs

Boundary Wires

(Twisted)

Boundary

Wire

Terminals

Transmitter

Wires

(Twisted)

Boundary Wire

Loop

Black 

Transmitter

Tabs

LP-4100

Power

Jack

Transmitter

Loop

4A

Содержание PIG00-10777

Страница 1: ...stubborn dog in ground fence operating and training guide Model Number PIG00 10777 PLEASE READ THIS ENTIRE GUIDE BEFORE BEGINNING...

Страница 2: ...can carry high voltage Have all underground cables marked before you dig to bury your wire In most areas this is a free service Avoid these cables when you dig Follow all safety instructions for your...

Страница 3: ...r pet may receive an unintended correction The Boundary Width of the system must be tested whenever an adjustment is made to the containment field to prevent unintended corrections to your pet If you...

Страница 4: ...he Boundary Flags 18 Fit the Receiver Collar 19 Training Guide 20 Be Patient With Your Pet 20 Day 1 Boundary Awareness 21 Days 2 thru 4 Continue Boundary Awareness 21 Days 5 thru 8 Distraction Phase 2...

Страница 5: ...ASE REA D THI S ENTIR E GU IDE BEF OR E BEG INN ING Mo del Num ber PIG00 10777 Other Items You May Need Additional wire and flags Part PIG00 13769 Tape measure Small Phillips screwdriver Drill mounti...

Страница 6: ...ed with the Fence Transmitter to protect it from lightning strikes and power surges USA and Canada only Receiver Collar Receives the radio signal from the Boundary Wire Correction Level Button Adjusts...

Страница 7: ...consistency 1C To mount the Fence Transmitter screw the mounting bracket onto a stationary surface such as a wall and slide the Fence Transmitter onto the bracket Once you have mounted the Fence Tran...

Страница 8: ...pet we recommend setting a Boundary Width for the Warning and Static Correction Zones to approximately 12 20 feet 6 to 10 feet on each side of the wire Avoid making passageways too narrow for your pet...

Страница 9: ...st 5 feet Twist the wire from A back to the Fence Transmitter E B D C A 5 2H Sample 5 2H Lake Access Double Loop From the Fence Transmitter run the wire to A A to B make a U turn and go to C C to D D...

Страница 10: ...to something secure and insert the other end in a power drill Pull the wire taut The drill enables you to twist the wire quickly Twist the Boundary Wire 10 to 12 times per foot to cancel the signal On...

Страница 11: ...nstall connect or remove your system during a lightning storm If the storm is close enough for you to hear thunder it is close enough to create hazardous surges Turn off power to outlet before you ins...

Страница 12: ...nections will result in an increased risk of surge related damage 5 Determine the length of wire needed to pass from the Surge Protector to the Fence Transmitter Measure and cut 2 lengths of wire then...

Страница 13: ...Lights should come on If this does not happen see the Troubleshooting section Do not install connect or remove your system during a lightning storm If the storm is close enough for you to hear thunder...

Страница 14: ...led press the Correction Level Button and release when the Receiver Indicator Light lights up 5E 3 The Receiver Indicator Light will emit a series of flashes representing the Static Correction Level 4...

Страница 15: ...ne if the collar is set at level 2 or above The Run Through Prevention sound is an intermittent tone Over Correction Protection In the unlikely event that your pet freezes in the Static Correction Zon...

Страница 16: ...warning tone you have identified the Boundary Width distance Static Correction Zone Two seconds after the warning tone the test light will begin to flash This flashing light can aid you in identifyin...

Страница 17: ...ce The Boundary Wire of the PetSafe Stubborn Dog In Ground Fence System can be attached to a chain link fence split rail fence or a wooden privacy fence The Boundary Wire can be attached as high as ne...

Страница 18: ...before burying 7C 7D Place the Boundary Flags The Boundary Flags are visual reminders for your pet of where the Warning Zone is located 1 Place the Test Light contacts on the contact points and hold t...

Страница 19: ...comfortable while they wear stainless steel contacts Some pets are sensitive to contact pressure You may find after some time that your pet is very tolerant of the collar If so you may relax some of t...

Страница 20: ...slow down the training schedule add additional days of training or increase the amount of play time with your pet in the Pet Area Common stress signals include Pet pulling on leash toward the house E...

Страница 21: ...rection Zone the Receiver Collar will begin to beep and vibrate 10B Allow your pet to stay in the Static Correction Zone for up to 2 seconds then gently help him back into the Pet Area 10C Immediately...

Страница 22: ...treats available hot dogs or lunch meat work well Have your pet s favorite play toy available Create distractions to tempt your pet to enter the Static Correction Zone such as Have a family member cro...

Страница 23: ...atisfied your pet s training is complete remove every other Boundary Flag every 4 days until all flags are removed Save Boundary Flags for future use Taking Your Pet Out of the Pet Area Important Remo...

Страница 24: ...as to be held on top of the Boundary Wire perform the System Test The Receiver Collar activates inside the house Turn the Boundary Width Control knob counterclockwise to decrease the distance from the...

Страница 25: ...ge 26 to determine if the Fence Transmitter or Surge Protector needs to be replaced If the Fence Transmitter is functioning properly you have a break in your Boundary Wire See the Wire Break Location...

Страница 26: ...Turn the Boundary Width Control knob to 10 and repeat Step 7 The distance where the Receiver Collar activates should be greater than the previous result 9 If more than one Receiver Collar is used on...

Страница 27: ...s 2 Where the wires cross sidewalks or driveways due to edging and string trimmers 3 Around landscaping and flower beds due to digging or working up the soil 4 At wire splices where Gel filled capsule...

Страница 28: ...ent shall Radio Systems Corporation or any of its associated companies be liable for i any direct indirect punitive incidental special or consequential damage and or ii any loss or damages whatsoever...

Страница 29: ...and on the user is encouraged to try to correct the interference by one or more of the following measures Relocate the interfered receiving antenna Increase the separation between the equipment and re...

Страница 30: ...that Radio Systems does not provide refunds replacements or upgrades for change of mind or for any other reason outside of these Warranty terms Claims Procedure Any claim made under this Warranty sho...

Страница 31: ...petsafe com 31 Layout Grid...

Страница 32: ...27 PetSafe Way Knoxville TN 37932 1 800 732 2677 petsafe com For a list of patents protecting this product please visit www radiosystemscorporation com patents J400 1416 6 2018 Radio Systems Corporati...

Отзывы: