VersiSafe
13
UL -Data
The safety functions were not evaluated by UL. Listing is accomplished according to
requirements of Standard UL 508, „general use apllications“.
Measuring-/Motor voltage:
max. AC 600V
Ambient temperature:
-25 ... +60°C, (+40°C with max. contact current,
see Derating)
Switching capacity
safety contacts
(11/12, 23/24, 33/34, 43/44)
Ambient temperature 40°C:
Pilot duty B300
5A 250VAC G.P.
5A 24VDC G.P.
Ambient temperature 60°C:
Pilot duty B300
2A 250VAC G.P.
2A 24VDC G.P.
Switching capacity
indicator contact (53/54):
3A 250VAC G.P.
Wire connection:
60°C / 75°C copper conductors only
Fixed screw terminal:
1x AWG 20 - 12 Sol/Str Torque 0.8 Nm or
2x AWG 20 - 14 Sol/Str Torque 0.8 Nm
Device with auxiliary
voltage Uh 24V DC:
Device must be supplied with a Class 2 or a Voltage /
Current limeted Power Supply.
Info:
Technical data that is not stated in the UL-Data, can be found in the
technical data section.