PestWest Chameleon Sirius Скачать руководство пользователя страница 3

Chameleon Sirius

Replacement of the cover is the opposite 
procedure of removal.

It may also be beneficial to rotate the cover 
when mounting the unit in the vertical 
orientation, if for example the unit is being 
located near to the corner of a room, which 
would otherwise limit access when replacing 
the glue board. 

INSTRUCTIONS FOR HARDWIRING  

THE UNIT

 

The unit also has the option of being wired 
through a knockout in the rear panel to allow 
connection directly into the buildings fixed 
wall light wiring. A knockout is provided for 
this on the rear panel and a terminal block can 
be found inside the enclosure for the electrical 
connections. If this option is used it should be 
performed by a qualified electrician and the 
existing power cord should be removed from 
the product and discarded. Ensure the unit is 
properly earthed.

CAUTION - Ensure the mains power supply is 

switched off at the fuse box and remove the 

fuse or circuit breaker protecting the circuit.

Firstly, the unit must be disassembled by 
removing both the front cover and reflector 
components.

Unscrew the 4 screws which are securing the 
cover to the mount panel using a pozidrive 
screwdriver, the cover can now be removed. 
Place the cover front side down on a soft, debris 
free surface to avoid any scratching of the cover. 
Remove the two tubes and place to one side. 

Next, unscrew the 4 remaining screws securing 
the reflector.

The reflector can then be moved to gain 
access to the internal wiring. If greater access is 
required, the lamp holders can be removed by 
depressing the plastic retaining clips holding 
them in place with a small flat screwdriver. If this 
is done, take care to depress the clips gently as 
they may snap if overloaded. 

Unscrew the small screws on the connector 
block which are holding in place the live and 
neutral wires leading from the power cable and 
pull them out of the connector block.  

Next unfasten the M4 Nut which is securing the 
green/yellow earth wires. Remove the Nut, the 
top spring washer and the earth wire leading 
from the power cable. Leave the second earth 
wire in place. 

The power cable can now be removed from the 
unit by compressing the strain relief bush. This 
cable should now be discarded.

The knockout panel should then be removed 
by wedging a flat head screwdriver into the 
knockout slit and tapping the screwdriver with a 
hammer gently. Excessive force may deform the 
mount panel. Once the edge of the knockout is 
bent, you can then grip the corner with pliers 
and twist until the securing tabs break loose. If 
the edges of the hole are sharp, they should be 
gently filed down to ensure no wires can be cut 
or damaged.

WIRING DIAGRAM 

To rewire the unit, the fixed wiring cable should 

be ran through the knockout and the earth 

should be connected back to the earth stud 

on the bodywork using an appropriate ring 

terminal connector as before, securing it with 

both the spring washer and M4 Nut provided. 

Check that the unit is fully earthed and both 

earth wires are secured before continuing 

with installation. Once earthed, the Live and 

Neutral cables can then be reconnected to the 

connector block as before. Ensure all cables are 

securely fastened by firmly tugging on them. 

None of the cables running from the ballast OR 

between the connector block and the switch 

should be tampered with.

Once the unit is safely rewired, it can then 

be reassembled. Assembly is the opposite 

procedure of disassembly. 

CLEANING AND MAINTENANCE 

To maintain the attractive appearance of the 

units, wipe down and clean as often as required. 

Use a cloth dampened with water and detergent 

or a proprietary cleaner. Do not use scouring 

pads or abrasives. 

The UV tubes in electric fly traps should be 

changed at least once per year, to maintain 

maximum efficiency replace with Quantum BL 

tubes.  Tubes are most attractive to the target 

flying insects when less than one year old. This 

is because the UV light emitted by the tubes at a 

wavelength of 350-375 nanometres diminishes 

with use.  Light of this wavelength is invisible to 

the human eye.  

Daily switching on and off of the lamps results 

in an even faster loss of the effective UV 

emission. Therefore leave the tubes switched 

on continuously and change them at least once 
per year (preferably at the onset of increased fly 
activity after the winter).

PestWest offer both standard tubes and 
shatterproof (coated) Quantum BL tubes.  The 
shatterproof tube is intended for use in glass 
exclusion zones.  

The coating on tubes supplied by PestWest is of 
the highest quality available, using a material, 
FEP that is both UV and operating temperature 
tolerant, whilst allowing high emissions of the 
critical UV light.  Replacements should be of 
similar performance.

RENEWING STICKY BOARDS 

Switch off the machine before servicing. 

Sticky boards should be changed when full or at 
least every 6-8 weeks. Regular inspections of the 
sticky boards are recommended, as they are not 
visible in normal operation.

Remove the old sticky board by lifting it out of 
the guides on the reverse side of the cover.

 (VIEW FROM REAR OF COVER TO SHOW 

GUIDES AND BOARD POSITION)

All units in the PestWest Chameleon range use 
the same size glue board, with the exception 
of the 4x4 and EX G models. Always install 
PestWest branded glue boards to ensure peak 
efficiency. To fit the shape of the Chameleon 
Sirius, the sticky board has a perforated crease 
about 80mm in from one edge. The board must 
be torn along this perforation with the smaller 
section being discarded. 

Remove the backing paper from the new board 
and slide into the guides on the reverse side 
of the cover, inserting first the edge where the 
perforation line was. Ensure the glue surface is 
facing towards the lamp.

CHANGING TUBES 

Switch off the machine before servicing. 

Grasp and rotate each tube 90° in either 
direction until 2 clicks are heard.  The tubes may 
then be withdrawn by sliding out of the lamp 
holders. Installation is the opposite procedure 
to removal.

REPLACEMENT PARTS 

Sticky boards type: 135-000047 (PestWest 
Chameleon Board) 

Tube type: 130-000177 (PestWest Quantum BL 
14W 21”)

All PestWest units are guaranteed for 3 years 

(excluding tubes and boards).

*Manufacturer reserves the right to vary model 
specifications without notice.

INSTRUCTIONS FOR USE AND MAINTENANCE  *  PLEASE SWITCH OFF MACHINE BEFORE SERVICING

Содержание Chameleon Sirius

Страница 1: ...ONS FOR USE INSTRUCTIONS FOR USE GEBRUIKSAANWIJZING INSTRUCCIONES ISTRUZIONI PER L USO BEDIENUNGSANLEITUNG NOTICE D INSTRUCTIONS INSTRUKCJA OBS UGI PestWest Electronics Ltd operates a quality manageme...

Страница 2: ...Observe where the flies tend to congregate and if possible put your flytrap in or close to that area Site the units near where flies are likely to gain access e g doors and windows opening to the out...

Страница 3: ...h installation Once earthed the Live and Neutral cables can then be reconnected to the connector block as before Ensure all cables are securely fastened by firmly tugging on them None of the cables ru...

Страница 4: ...door de paragraaf Plaatsing te raadplegen De Chameleon Sirius wordt geleverd met een wisselstroomkabel van 2 meter lang waarvan n uiteinde eindigt met een stekker die toelaat om deze te verbinden aan...

Страница 5: ...geen schuurmiddel of schuursponsje De UV lampbuizen moeten minimaal 1x per jaar worden vervangen Om de efficientie van het toestel te behouden moet deze uitgerust zijn met Quantum BL lampbuizen Dit v...

Страница 6: ...atraer a las moscas fuera de zonas sensibles en vez de hacia ellas F jese en donde se congregan las moscas y si es posible coloque el aparato all o lo m s cerca posible Coloque el aparato en una posic...

Страница 7: ...elo con un trapo humedecido con agua y detergente o un limpiador de marca No use trapos o limpiadores abrasivos Se recomienda cambiar los tubos fluorescentes de luz ultravioleta por lo menos cada a o...

Страница 8: ...e PestWest montano tubi Quantum BL infrangibili con rivestimento FEP come da standard EN61549 La Chameleon Sirius offre la pi recente tecnologia di tubi T5 ad alta efficienza energetica Questi tubi so...

Страница 9: ...olta che l unit cablata in modo sicuro si pu allora riassemblarla Il procedimento di montaggio l opposto della procedura di smontaggio PULIZIA E MANUTENZIONE Per mantenere l aspetto piacevole delle un...

Страница 10: ...licht m glichst gering ist In Lebensmittelbereichen sollte das Ger t in der N he von aber nicht direkt ber offenen Lebensmitteln und Lebensmittelzubereitungsfl chen platziert werden Die Fliegen sollte...

Страница 11: ...t werden REINIGUNG UNDWARTUNG Um das attraktive Erscheinungsbild der Ger te zu erhalten sollten sie so oft wie n tig gereinigt bzw abgewischt werden Verwenden Sie dazu ein angefeuchtetesTuch mit etwas...

Страница 12: ...ont susceptibles de p n trer c est dire pr s des portes et fen tres ouvertes sur l ext rieur notamment en cas de pr sence de conteneurs d chets Attention toutefois ne pas attirer les insectes de l ext...

Страница 13: ...ermement Aucun des fils lectriques provenant du ballast ou reliant la barrette et l interrupteur ne doivent tre manipul s Lorsque l appareil a t s rement reconnect il peut alors tre r assembl Pour l a...

Страница 14: ...t p innych r de wiat a jest minimalny lub ograniczony W pomieszczeniach gdzie jest ywno lampy nale y montowa blisko ale nie bezpo rednio nad odkryt ywno ci najlepiej tak aby odci ga owady od miejsc pr...

Страница 15: ...lowania urz dzenie mo na ponownie z o y poprzez wykonanie wy ej opisanej procedury w odwrotnej kolejno ci CZYSZCZENIEIKONSERWACJA Dla osi gni cia atrakcyjnego wygl du lamp nale y je czy ci i my tak cz...

Страница 16: ...PestWest 6 8 PestWest PestWest 304 PestWest PestWest EN61549 The Chameleon Sirius 5 24 The Chameleon Sirius PestWest Chameleon Sirius 2 220 240 50 60 3 40 5 5 10 Chameleon Sirius...

Страница 17: ...4 4 350 375 PestWest PestWest 6 8 PestWest Chameleon 4 4 EX G PestWest 80 90 135 000047 PestWest Chameleon 130 000177 PestWest 14 21 PestWest 3...

Страница 18: ...Chameleon Sirius...

Страница 19: ......

Страница 20: ...n Fly Control PestWest Electronics Limited West Yorkshire United Kingdom Office 44 0 1924 268500 email info pestwest com www pestwest com Version 01 AUG2016 PestWest Electronics Ltd operates a quality...

Отзывы: