Reentry
An entity which exists as both a source and destination at the same time, whose function is to
facilitate switching a single source to multiple destinations, with a single logical switch.
Reentries are virtual entities that exist in the control software only. Their creation and use does not
require any physical modification to the switching system hardware.
Example: Assume the existence of source SRC1 and destinations DST1, DST2, and DST3.
Reentry REENT1 is created and switched to the three destinations. With a single logical switch,
SRC1 can now be switched to REENT1 and the signal will arrive at all three destinations at the
same time.
A reentry is assigned both a source number and a destination number.
Reentry names are constructed using one category followed by 0, 1 or 2 indices. If no index is
selected, the default “00” (which is not displayed) will be used.
Remote Modem
A modem connected to a 3500Plus System Controller.
The remote modem must be an external type capable of being configured to automatically answer
incoming calls. Because the 3500Plus System Controller does not output any modem
configuration information, the remote modem must be completely transparent to the controller.
The only modems tested by PESA for use as remote modems are the Practical Peripherals
PM288MT II and the U.S. Robotics Sportster 28.8 using the following initialization strings:
PM288MT II: AT S0=2 Q1 X4 &C1 &D0 &K3 &S1 &W0 &Y0
Sportster 28.8: AT &F1 S0=2 &H1 &R2 &I0 L2 Q1 &C1 &D0 Y0 &W0
For more information about these modems and their initialization strings, see the Practical
Peripherals web site at http://www.practical.com/ or the U.S. Robotics web site at
http://www.usr.com/. Before using any other type of modem for the remote modem, please consult
with the PESA Customer Service Department.
Once a remote modem has been selected, it must be properly configured before it is connected to a
3500Plus System Controller. This is done by connecting the remote modem to a PC running
Win3500Plus, transferring certain data into the remote modem, disconnecting the remote modem
from the PC, and then connecting the remote modem to the controller.