page 2.14
3/98
P/N 81905903730
INSTALLATION
2
Section 2
Installation
Jaguar Audio
Figure 2-10 Output Monitor Card Input Code Selection
2.12 Output Monitor Card Input/Output Coding Select.
The Output Monitor Card's input and output code select switches are
located on the front edge of the Output Monitor Card. For all switch posi-
tion to binary code conversions refer to Table 2-3.
The input and output switch numbers run 1 to 8, left to right. Switch S2
(input code switch) selects input codes 0-255 and switch S1 (output code
switch) selects output codes 0-255. Refer to Figures 2-10 and 2-11 for
examples of input and output code selection and see Figure 2-9 for the
physical location of the output and input code switches.
Input Code
Physical 0 (Logical 1) = OFF (DOWN)
Physical 1 (Logical 0) = ON (UP)
NOTE: The following are logical selections. Input code 0 is all switches on
(up) or all switches in the physical 1 position.
SWITCH POSITION 1
2
3
4
5
6
7
8
INPUTS
INPUT CODE 0
0
0
0
0
0
0
0
0
1-64
INPUT CODE 1
1
0
0
0
0
0
0
0
65-128
INPUT CODE 2
0
1
0
0
0
0
0
0
129-192
INPUT CODE 3
1
1
0
0
0
0
0
0
193-256
INPUT CODE 4
0
0
1
0
0
0
0
0
257-320
INPUT CODE 5
1
0
1
0
0
0
0
0
321-384
INPUT CODE 6
0
1
1
0
0
0
0
0
385-448
INPUT CODE 7
1
1
1
0
0
0
0
0
449-512
UP TO....
OUTPUT CODE 14 0
0
0
0
1
1
1
0
961-1024